In light of the severity of coronavirus disease (COVID-19) around the world, it is an arduous task for China to prevent COVID-19 from being imported from abroad and proliferating domestically. The community is the first and most effective line of defense and can effectively cut off the channels of spread of the epidemic. In order to reduce risks of COVID-19 transmission in the community, it is necessary to sort out the loopholes in risk and management, as well as investigate previous epidemic transmission events in the community.
SARS-CoV-2 genetic sequence results collected from native COVID-19 cases who waited or saw relatives off at Xi’an Xianyang International Airport were highly consistent with the imported cases. In order to explore the routes of transmission and influencing factors that may cause the transmission of SARS-CoV-2 at the airport, a field simulation experiment of aerosol diffusion was adopted based on epidemiological survey data and a detailed field investigation of airport structure and ventilation. The results showed that the inbound passengers waited for approximately 3 h in the rest area on the first level of the international arrival area (Zone E). During the period, masks were removed for eating and drinking, resulting in the viral aerosols rising from the first level to the second level with hot air. After deplaning, the inbound passengers handled the relevant procedures and passed through the corridor on the second floor. The local side wall of the corridor adopted fan coil air conditioning, combined with fresh air supply and personnel walking, resulting in airflow flowing to Zone E. After merging with diffused air containing virus aerosol from the first floor, it continued to spread upward to the connected third-layer area. There was a local suspended ceiling on the top of the third floor, but it was approximately 4 m high and connected to the corridor from Terminal 2 to Terminal 3. When the virus aerosol diffused above the Terminal 2–Terminal 3 corridor, where the temperature was low and the air diffused downward, it could cause an infection risk for people passing through the corridor. In addition, the investigation found that the exhaust pipes of the nucleic acid sampling rooms at the international arrival corridor were directly discharged outdoors without treatment. Only one exhaust pipe and poor ventilation in the bathroom in Zone E had a risk of viral aerosol diffusion. Therefore, the international arrival area should be set up alone or separated from the other areas by hard isolation to avoid the existence of communication between different areas that could cause viral aerosols to diffuse with airflow. The toilet ventilation should be increased to avoid the accumulation of viral aerosols at high concentrations. The exhaust pipes of the toilet and the nucleic acid sampling rooms should be equipped with disinfection and efficient filtration devices, and high-altitude emission should be adopted to reduce the risk of virus aerosol diffusion.
During the COVID-19 pandemic, many buildings in northeast China have had clusters of infected cases in the vertical layout. There is speculation that vertical aerosol transmission occurs. The houses in northeast China are airtight, and range hoods may be used for a long period of time when cooking. The pathway and factors influencing vertical aerosol transmission are worth studying. To elucidate a viral aerosol transmission pathway, we selected a multistory apartment and a high-rise building in Changchun city, Jilin province, China, to conduct an in-depth investigation and on-site simulation experiments. According to epidemiological investigation information on infected cases, building structures, drainage, ventilation, etc., we used fluorescent microspheres to simulate the behaviors of infected people, such as breathing and flushing the toilet after defecation, to discharge simulated viruses and track and monitor them. The field simulation experiment confirmed the transmission of fluorescent microsphere aerosols to other rooms in two types of buildings using a vertical aerosol transmission pathway of toilet flush-sewage pipe-floor drain without a water seal. Our study showed that, in the absence of a U-shaped trap or floor drain water seal whether in a multistory apartment or high-rise residential building, there is a transmission pathway of “excretion of virus through feces-toilet flushing-sewage pipe-floor drain without water seal,” which will cause the vertical transmission of viral aerosol across floors during the COVID-19 pandemic. Moreover, the negative pressure generated by turning on the range hood when closing doors and windows increase aerosol transmission. Based on this negative pressure, prevention and control measures for residential buildings in northeast China during the COVID-19 pandemic were proposed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.