on behalf of the Multicenter InSync ICD II Study GroupBackground-The effects of cardiac resynchronization therapy (CRT) in patients with mildly symptomatic heart failure have not been fully elucidated. Methods and Results-The Multicenter InSync ICD Randomized Clinical Evaluation II (MIRACLE ICD II) was a randomized, double-blind, parallel-controlled clinical trial of CRT in NYHA class II heart failure patients on optimal medical therapy with a left ventricular (LV) ejection fraction Յ35%, a QRS Ն130 ms, and a class I indication for an ICD. One hundred eighty-six patients were randomized: 101 to the control group (ICD activated, CRT off) and 85 to the CRT group (ICD activated, CRT on). End points included peak V O 2 , V E/V CO 2 , NYHA class, quality of life, 6-minute walk distance, LV volumes and ejection fraction, and composite clinical response. Compared with the control group at 6 months, no significant improvement was noted in peak V O 2 , yet there were significant improvements in ventricular remodeling indexes, specifically LV diastolic and systolic volumes (Pϭ0.04 and Pϭ0.01, respectively), and LV ejection fraction (Pϭ0.02). CRT patients showed statistically significant improvement in V E/V CO 2 (Pϭ0.01), NYHA class (Pϭ0.05), and clinical composite response (Pϭ0.01). No significant differences were noted in 6-minute walk distance or quality of life scores. Conclusions-In patients with mild heart failure symptoms on optimal medical therapy with a wide QRS complex and an ICD indication, CRT did not alter exercise capacity but did result in significant improvement in cardiac structure and function and composite clinical response over 6 months.
The STOP AF trial demonstrated that cryoballoon ablation is a safe and effective alternative to antiarrhythmic medication for the treatment of patients with symptomatic paroxysmal AF, for whom at least one antiarrhythmic drug has failed, with risks within accepted standards for ablation therapy. (A Clinical Study of the Arctic Front Cryoablation Balloon for the Treatment of Paroxysmal Atrial Fibrillation [Stop AF]; NCT00523978).
Comprehensive review of the CB2 ablation best practice guide will provide a detailed technique for achieving safer and more effective outcomes for CB2 atrial fibrillation ablation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.