Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is a hybrid mass spectrometry ionization source that combines the benefits of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) making it a great analytical tool for high-throughput screening (HTS) analyses. IR-MALDESI is coupled to an Orbitrap Exploris 240 mass spectrometer that utilizes a bent quadrupole (C-trap) to inject accumulated ions into the high-field Orbitrap mass analyzer. Here, we present a study on the optimized C-trap timing for HTS analyses by IR-MALDESI mass spectrometry. The timing between initial ion generation and the C-trap opening time was optimized to reduce unnecessary ambient ion accumulation in the mass spectrometer. The time in which the C-trap was held open, the ion accumulation time, was further optimized to maximize the accumulation of analyte ions generated using IR-MALDESI. The resulting C-trap opening scheme benefits small-molecule HTS analyses by IR-MALDESI by maximizing target ion abundances, minimizing ambient ion abundances, and minimizing the total analysis time per sample. The proposed C-trap timing scheme for HTS does not translate to large molecules; a NIST monoclonal antibody standard reference material was analyzed to demonstrate that larger analytes require longer ion accumulation times and that IR-MALDESI can measure intact antibodies in their native state.
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both highthroughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide m/z range. Finally, documentation is provided for each NextGen IR-MALDESI part so that it can be replicated and incorporated into any lab space.
Native Americans domesticated maize ( Zea mays ssp. mays ) from lowland teosinte parviglumis ( Zea mays ssp. parviglumis) in the warm Mexican southwest and brought it to the highlands of Mexico and South America where it was exposed to lower temperatures that imposed strong selection on flowering time. Phospholipids are important metabolites in plant responses to low-temperature and phosphorus availability and have been suggested to influence flowering time. Here, we combined linkage mapping with genome scans to identify High PhosphatidylCholine 1 ( HPC1 ), a gene that encodes a phospholipase A1 enzyme, as a major driver of phospholipid variation in highland maize. Common garden experiments demonstrated strong genotype-by-environment interactions associated with variation at HPC1, with the highland HPC1 allele leading to higher fitness in highlands, possibly by hastening flowering. The highland maize HPC1 variant resulted in impaired function of the encoded protein due to a polymorphism in a highly conserved sequence. A meta-analysis across HPC1 orthologs indicated a strong association between the identity of the amino acid at this position and optimal growth in prokaryotes. Mutagenesis of HPC1 via genome editing validated its role in regulating phospholipid metabolism. Finally, we showed that the highland HPC1 allele entered cultivated maize by introgression from the wild highland teosinte Zea mays ssp. mexicana and has been maintained in maize breeding lines from the Northern United States, Canada, and Europe. Thus, HPC1 introgressed from teosinte mexicana underlies a large metabolic QTL that modulates phosphatidylcholine levels and has an adaptive effect at least in part via induction of early flowering time.
Deconvolution from intact protein mass-to-charge spectra to mass spectra is essential to generate interpretable data for mass spectrometry (MS) platforms coupled to ionization sources that produce multiply charged species. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) can be used to analyze intact proteins in multiwell microtiter plates with speed matching small molecule analyses (at least 1 Hz). However, the lack of compatible deconvolution software has limited its use in high-throughput screening applications. Most existing automated deconvolution software packages work best for data generated from LC–MS, and to the best of our knowledge, there is no software capable of performing fast plate-based mass spectral deconvolution. Herein we present the use of a new workflow in ProSight Native for the deconvolution of protein spectra from entire well plates that can be completed within 3 s. First, we successfully demonstrated the potential increased throughput benefits produced by the combined IR-MALDESI-MS - ProSight Native platform using protein standards. We then conducted a screen for Bruton’s tyrosine kinase (BTK) covalent binders against a well-annotated compound collection consisting of 2232 compounds and applied ProSight Native to deconvolute the protein spectra. Seventeen hits including five known BTK covalent inhibitors in the compound set were identified. By alleviating the data processing bottleneck using ProSight Native, it may be feasible to analyze and report covalent screening results for >200,000 samples in a single day.
Mass spectrometry imaging (MSI) data visualization relies on heatmaps to show the spatial distribution and measured abundances of molecules within a sample. Nonuniform color gradients such as jet are still commonly used to visualize MSI data, increasing the probability of data misinterpretation and false conclusions. Also, the use of nonuniform color gradients and the combination of hues used in common colormaps make it challenging for people with color vision deficiencies (CVDs) to visualize and accurately interpret data. Here we present best practices for choosing a colormap to accurately display MSI data, improve readability, and accommodate all CVDs. We also provide other resources on the misuse of color in the scientific field and resources on scientifically derived colormaps presented herein.
Two-dimensional mass spectrometry imaging (2D MSI) experiments mainly involve samples with a flat surface and constant thickness, but some samples are challenging to section due to the texture and topography. Herein, we present an MSI method that automatically corrects for discernible height differences across surfaces during imaging experiments. A chromatic confocal sensor was incorporated into the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) system to measure the sample surface height at the location of each analytical scan. The height profile is subsequently used for adjusting the z-axis position of the sample during MSI data acquisition. We evaluated this method using a tilted mouse liver section and an unsectioned Prilosec tablet due to their exterior quasi-homogeneity and height differences of approximately ∼250 μm. MSI with automatic z-axis correction showed consistent ablated spot sizes and shapes, revealing the measured ion spatial distribution across a mouse liver section and a Prilosec tablet. Conversely, irregular spots and reduced signals with large variability were observed when no z-axis correction was applied.
Mass spectrometry (MS) is an effective analytical tool for high‐throughput screening (HTS) in the drug discovery field. Infrared matrix‐assisted laser desorption electrospray ionization (IR‐MALDESI) MS is a high‐throughput platform that has achieved analysis times of sub‐seconds‐per‐sample. Due to the high‐throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR‐MALDESI‐MS analyses to improve data quality and reduce false‐positive hits. The Z‐factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR‐MALDESI‐MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR‐MALDESI‐MS in both positive and negative ionization modes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.