Many emerging applications in the terahertz (THz) frequency range demand highly sensitive, broadband detectors for room-temperature operation. Field-effect transistors with integrated antennas for THz detection (TeraFETs) have proven to meet these requirements, at the same time offering great potential for scalability, high-speed operation, and functional integrability.
We present broadband high sensitivity terahertz (THz) detectors based on 90 nm CMOS technology with the state-of-the-art performance. The devices are based on bow-tie and log-spiral antenna-coupled field-effect transistors (FETs) for the detection of free-space THz radiation (TeraFETs). We report on optimized performance, which was achieved by employing an in-house developed physicsbased model during detector design and thorough device characterization under THz illumination. The implemented detector with bow-tie antenna design exhibits a nearly flat frequency response characteristic up to 2.2 THz with an optical responsivity of 45 mA/W (or 220 V/W). We have determined a minimum optical noise-equivalent power as low as 48 pW/ √ Hz at 0.6 THz and 70 pW/ √ Hz at 1.5 THz. The results obtained at 1.5 THz are better than the best narrowband TeraFETs reported in the literature at this frequency and only up to a factor of four inferior to the best narrowband devices at 0.6 THz.
This paper presents an overview of the different methods used for sensitivity (i.e., responsivity and noise equivalent power) determination of state-of-the-art field-effect transistor-based THz detectors/sensors. We point out that the reported result may depend very much on the method used to determine the effective area of the sensor, often leading to discrepancies of up to orders of magnitude. The challenges that arise when selecting a proper method for characterisation are demonstrated using the example of a 2×7 detector array. This array utilises field-effect transistors and monolithically integrated patch antennas at 620 GHz. The directivities of the individual antennas were simulated and determined from the measured angle dependence of the rectified voltage, as a function of tilting in the E- and H-planes. Furthermore, this study shows that the experimentally determined directivity and simulations imply that the part of radiation might still propagate in the substrate, resulting in modification of the sensor effective area. Our work summarises the methods for determining sensitivity which are paving the way towards the unified scientific metrology of FET-based THz sensors, which is important for both researchers competing for records, potential users, and system designers.
We propose to exploit rectification in field-effect transistors as an electrically controllable higher-order nonlinear phenomenon for the convenient monitoring of the temporal characteristics of THz pulses, for example, by autocorrelation measurements. This option arises because of the existence of a gate-bias-controlled super-linear response at sub-threshold operation conditions when the devices are subjected to THz radiation. We present measurements for different antenna-coupled transistor-based THz detectors (TeraFETs) employing (i) AlGaN/GaN high-electron-mobility and (ii) silicon CMOS field-effect transistors and show that the super-linear behavior in the sub-threshold bias regime is a universal phenomenon to be expected if the amplitude of the high-frequency voltage oscillations exceeds the thermal voltage. The effect is also employed as a tool for the direct determination of the speed of the intrinsic TeraFET response which allows us to avoid limitations set by the read-out circuitry. In particular, we show that the build-up time of the intrinsic rectification signal of a patch-antenna-coupled CMOS detector changes from 20 ps in the deep sub-threshold voltage regime to below 12 ps in the vicinity of the threshold voltage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.