Pilot‐scale data were generated to improve operational guidance for fine bubble diffusion (FBD) and sidestream addition (SSA) systems with respect to unaccounted‐for ozone exposure—i.e., concentration times time (C × T), and bromate formation during ozone dissolution. In FBD systems, results showed significant ozone dissolution C × T (0.31–2.85 mg‐min/L) and bromate formation (0.8–9.1 µg/L) occurring in the bubble column, which is not included in regulatory compliance C × T calculations. Utilities may consider taking contactors out of service to minimize contact time and corresponding bromate formation in the dissolution zone. In SSA systems, ozone dosages (7.2–18.6 mg/L) were transferred to approximately 20% of the overall plant flow for ~5 s, which produced bromate (2.6–5.7 µg/L). As the contact time exceeded the design guidance in the sidestream flow (>30 s), bromate formation became far more significant (40–140 µg/L). When the sidestream flow is operated with short contact times (~5 s), bromate formation can be minimized.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.