<p>Many older bridges are constructed with floor systems consisting of a non-composite concrete deck over steel girders. A potentially economical method for strengthening these bridges is to develop composite action by attaching the existing concrete deck to the steel beams using post-installed shear connectors. The current paper discusses this method based on the findings from a large-scale research study aimed at strengthening existing non- composite continuous steel girder bridges. The results of this research indicate that post- installed shear connectors are a feasible and efficient method of extending the useful service life of a non-composite steel girder bridge. Increases of more than 60-percent in the ultimate strength of the bridge girders tested in this study were attained by strengthening to a composite ratio of only 30-percent. The test program also exhibited excellent fatigue resistance for the post-installed shear connectors.</p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.