Background:It is a randomized study to compare cement penetration on x-rays after total knee arthroplasty (TKA) among 3 different ways to use tourniquets; application during the surgery, application only with implantation prosthesis and with no tourniquet use.Methods:A total 69 knees of 59 patients were included in the study in a quasirandom manner. Each patient had physical exams and standard radiographic evaluations at 6 weeks after the TKA procedure. Outcome evaluations included visual analog scale (VAS) scores, Knee Society Scores (KSS), blood transfusion, and drainage status after surgery for all groups. For radiographic review, the tibial plateau was divided into zones in the anterior–posterior and lateral views, according to the Knee Society Scoring System.Results:The average age of the patients who were eligible for the study was 65.05 (range 46–81) years. All 59 patients included in the study were female patients. Group 1 consisted of 24 patients who had TKA with use of a tourniquet during the entire operation. Group 2 consisted of 20 patients who had TKA with use of tourniquet only at the time of cementing and group 3 consisted of 25 patients with no use tourniquet. There is no significant difference in early cement penetration among the groups (group 1 2.50 mm, group 2 2.28 mm, group 3 2.27 mm; group 1 vs 2 P = .083, group 1 vs 3 P = .091, group 2 vs 3 P = .073). There is no significant difference for postoperative drainage among the 3 groups (group 1 245 mL, group 2 258.76 mL, group 3 175.88 mL; group 1 vs 2 P = .081, group 1 vs 3 P = .072, group 2 vs 3 P = .054). There was no need to transfuse more than 1 unit in any patient. The VAS score was significantly higher (group 1 3.58, group 2 1.55, group 3 1.52; group 1 vs 2 P = .022, group 1 vs 3 P = .018, group 2 vs 3 P = .062) and KSS was significantly lower in the tourniquet group (group 1 63, group 2 79, group 3 82; group 1 vs 2 P = .017, group 1 vs 3 P = .02, group 2 vs 3 P = .082).Conclusion:We do not suggest long-duration tourniquet use, which can lead higher pain scores and reduce functional recovery after total knee arthroplasty.
Background Infection after open fractures is a common complication. Treatment options for infections developed after intramedullary nailing surgery remain a topic of controversy. We therefore used a rat fracture model to evaluate the effects of infection on osseous union when the implant was maintained.Questions/purposes In a rat model, (1) does infection alter callus strength; (2) does infection alter the radiographic appearance of callus; and (3) does infection alter the histological properties of callus? Methods An open femoral fracture was created and fixed with an intramedullary Kirschner wire in 72 adult male Sprague-Dawley rats, which were divided into two study groups. In the infection group, the fracture site was contaminated with Staphylococcus aureus (36 animals), whereas in the control group, there was no bacterial contamination (36 animals). No antibiotics were used either for prophylaxis or for treatment. We performed biomechanical (maximum torque causing failure and stiffness), radiographic (Lane and Sandhu scoring for callus formation), and histologic (scoring for callus maturity) assessments at 3 and 6 weeks. The number of bacteria colonies on the femur, wire, and soft tissue inside knee were compared to validate that we successfully created an infection model. The number of bacteria colonies in the soft tissue inside the knee was higher in the infection group after 6 weeks than after the third week, demonstrating the presence of locally aggressive infection. Results Infection decreased callus strength at 6 weeks. Torque to failure (299.07 ± 65.53 Nmm versus 107.20 ± 88.81, mean difference with 95% confidence interval, 192 [43-340]; p = 0.007) and stiffness at 6 weeks (11.28 ± 2.67 Nmm versus 2.03 ± 1.68, mean difference with 95% confidence interval, 9 [3-16]; p = 0.004) both were greater in the control group than in the group with infection.
HighlightsFemoral neck stress fractures are not uncommon.Osteomalacia is a common cause of insufficiency fractures.Coxa vara is a rare cause of femoral neck stress fractures.Co-existence of osteomalacia and coxa vara is a rare condition.
We report the outcomes of mechanical prophylaxis and chemoprophylaxis in patients who underwent elective surgery for idiopathic adolescent scoliosis (AIS). We retrospectively studied the patients who underwent posterior spinal instrumentation for AIS. The patients were divided into three groups: Group A low-molecular-weight heparin (LMWH) started at 8 hours after surgery; Group B LMWH started at 24 hr after surgery; Group C did not receive chemoprophylaxis. The data about wound oozing, need for transfusion, preoperative and postoperative hemoglobin level, length of stay in hospital, interval from the surgery to removal of closed suction drainage tube, postoperative blood loss from closed suction drain, deep venous thrombosis (DVT), and pulmonary embolism (PE) were investigated. The mean age and Lenke classification for all the groups were similar. No DVT or PE was detected in any group. The mean blood loss from the drain was higher in Group A (400 mL) and Group B (450 mL) when compared to Group C (150 mL) ( P = .001). There were more wound oozing in Groups A (5) and B (6) than in Group C (3) ( P = .585). Three patients in Group B, 3 patients in Group A, and no patient in Group C had superficial infections. However, there was no statistical difference between the groups ( P = .182). Postoperative hospital stay was significantly longer in Groups A (6 days) and B (6 days) then in Group C (5 days) ( P = .001). Our current study claims that chemoprophylaxis is not necessary for the patients without risk factors after AIS surgery. Early mobilization and mechanoprophylaxis represents adequate prophylaxis in addition to pain management and well hydration in patients’ routine treatment. The complications of chemoprophylaxis are not correlated to the initiation time of prophylaxis.
HighlightsSkeletal deformity surgery is a difficult procedure which requires meticulous planning.Good results demand precise application of the surgical plan during the surgery.3D software helps to make precise surgical plans and design case specific surgical tools.3D printing of case specific tools renders surgery easy and precise.
ObjectiveTotal knee replacement (TKR) is a surgical treatment for final stage gonarthrosis. The lifespan of the prosthetic implants used in TKR surgery is a major interest for the orthopaedic research community.Previously, proper implant alignment of the implants has been advocated for longevity of the TKR surgery. Recently, patient-specific (PSI) instruments have been proposed to improve the mechanical alignment of the TKR by permitting better implant positioning over conventional TKR surgery. The aim of this study is to compare the mechanical alignment results of patients operated with PSIs and conventional instruments.MethodsTwo groups of 20 patients chosen in a quasi-random manner have been compared in this study. In the first group femoral distal and tibial osteotomies were made by a PSI which was produced by the patients' computed tomography scans. All osteotomies in the control group were made with the TKR set's routine instruments by conventional means. Patients' preoperative and postoperative mechanical femorotibal angles (mFTA), femoral coronal angles (FCA), tibial coronal angles (TCA) were measured and the number of outliers which showed more than 3° of malalignment were counted in both groups for comparison.ResultsThe average postoperative mFTA was found to be 2.09° for the PSI group and in was found to be 2.84° for the control which was not statistically significant. The comparison of postoperative FCA and TCA also did not show significant difference between the groups. The number of outliers showing more than 3° of malalignment per group were found to be 1 out of 20 (5%) for the PSI group and 7 out of 20 (35%) for the control which was statistically significant.ConclusionIn this study patient-specific instrumentation provided significantly better mechanical alignment compared to conventional TKR for the frequency of outlier cases with malalignment beyond 3°. PSI proved no significant difference when the groups were compared for mFTA, FCA and TCA. Our findings support that PSI may improve TKR alignment by improving the ratio of the outlier patients with marked malalignment.Level of EvidenceLevel III, Therapeutic Study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.