In this study, an improved and robust one-dimensional human arterial network model is presented. The one-dimensional blood flow equations are solved using the Taylor-locally conservative Galerkin finite element method. The model improvements are carried out by adopting parts of the physical models from different authors to establish an accurate baseline model. The predicted pressure-flow waveforms at various monitoring positions are compared against in vivo measurements from published works. The results obtained show that wave shapes predicted are similar to that of the experimental data and exhibit a good overall agreement with measured waveforms. Finally, computational studies on the influence of an abdominal aortic aneurysm are presented. The presence of aneurysms results in a significant change in the waveforms throughout the network.
Ventricular assist devices have become the standard therapy for end-stage heart failure. However, their use is still associated with severe adverse events related to the damage done to the blood by fluid dynamic stresses. This damage relates to both the stress magnitude and the length of time the blood is exposed to that stress. We created a dye washout technique which combines experimental and numerical approaches to measure the washout times of ventricular assist devices. The technique was used to investigate washout characteristics of three commercially available and clinically used ventricular assist devices: the CentriMag, HVAD and HeartMate II. The time taken to reach 5% dye concentration at the outlet (T05) was used as an indicator of the total residence time. At a typical level of cardiac support, 5 L/min and 100 mmHg, T05 was 0.93, 0.28 and 0.16 s for CentriMag, HVAD and HeartMate II, respectively, and increased to 5.06, 1.64 and 0.96 s for reduced cardiac support of 1 L/min. Regional variations in washout characteristics are described in this article. While the volume of the flow domain plays a large role in the differences in T05 between the ventricular assist devices, after standardising for ventricular assist device volume, the secondary flow path was found to increase T05 by 35%. The results explain quantitatively, for the first time, why the CentriMag, which exerts low shear stress magnitude, has still been found to cause acquired von Willebrand Syndrome in patients.
This paper numerically investigates non-Newtonian blood flow with oxygen and carbon dioxide transport across and along an array of uniformly square and staggered arranged fibers at various porosity (ε) levels, focussing on a low Reynolds number regime (Re < 10). The objective is to establish suitable mass transfer correlations, expressed in the form of Sherwood number (Sh = f(ε, Re, Sc)), that identifies the link from local mass transfer investigations to full-device analyses. The development of a concentration field is initially investigated and expressions are established covering the range from a typical deoxygenated condition up to a full oxygenated condition. An important step is identified where a cut-off point in those expressions is required to avoid any under- or over-estimation on the Sherwood number. Geometrical features of a typical commercial blood oxygenator is adopted and results in general show that a balance in pressure drop, shear stress, and mass transfer is required to avoid potential blood trauma or clotting formation. Different definitions of mass transfer correlations are found for oxygen/carbon dioxide, parallel/transverse flow, and square/staggered configurations, respectively. From this set of correlations, it is found that transverse flow has better gas transfer than parallel flow which is consistent with reported literature. The mass transfer dependency on fiber configuration is observed to be pronounced at low porosity. This approach provides an initial platform when one is looking to improve the mass transfer performance in a blood oxygenator without the need to conduct any numerical simulations or experiments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.