A neonate presented with early encephalopathy deteriorated and was intubated and ventilated. Ventilator data were monitored and recorded at 100 Hz for 24 hours.The infant had many sudden deep inspirations during this time which were initially thought to be seizures. These were characterised by short, rapid, large inspirations when the airway pressure was reduced well below the positive end expiratory pressure level. Analysis of the ventilator data showed that these were hiccupping episodes misinterpreted by the ventilator as spontaneous breaths and triggering ventilator inflations. The expired tidal volumes during the hiccupping episodes were more than double the set 4.5 mL/kg. During these episodes, there was no change in the level of consciousness or in the amplitude-integrated electroencephalogram signal. Detailed respiratory recording of pathological hiccups has not been reported.Metabolic screening diagnosed non-ketotic hyperglycinaemia. Hiccups commonly occur in this condition and should not be misinterpreted as seizures, spontaneous breaths or gasps.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.