Background Although drug-eluting stents dramatically reduce revascularization after percutaneous coronary intervention (PCI), it is still unclear whether they increase the risk of stent thrombosis. Late stent thrombosis (>30 days) was a very rare complication after bare metal stent implantation. Four cases of confirmed late angiographic stent thrombosis (LAST) after sirolimus-eluting stent (SES) implantation are presented and the incidence, promoting factors and outcomes of such cases in Japan, where clopidogrel has not been approved, are described.
Methods and ResultsBetween September 2004 and March 2006, 725 patients underwent PCI with SES implantation and 679 patients (94%) were clinically followed up (median 271 days). There were 4 cases (0.6%) of LAST (at 60, 180, 215, and 508 days, respectively) after elective SES implantation resulting in myocardial infarction. Three cases occurred soon after antiplatelet therapy discontinuation 3 patients died after LAST events. The incidence of LAST was 0.6%. Conclusions LAST is a rare complication, even after SES implantation, at least in patients with appropriate antiplatelet therapy. However, as it can lead to fatal complications, it must be taken into account, especially when antiplatelet therapy is discontinued. (Circ J 2007; 71: 226 -228)
Background-We recently developed a 4F child catheter that can be inserted into 6F or larger conventional guiding catheters.The use of 4F mother-child technique may improve the delivery of coronary stents to complex lesions. Accordingly, we sought to determine the potential of using a 4F mother-child technique to treat complex coronary lesions. Methods and Results-The support power and the trackability of the mother-child technique of 4-in-6 were evaluated using a coronary artery tree model. In addition, the results of 51 lesions treated by using a 4F child catheter were retrospectively analyzed. The in vitro experiment demonstrated that backup support of the 4-in-6 system was increased when the child catheter was advanced into the coronary tree Ն5 cm (PՅ0.01); further, the 4F child catheter was associated with superior trackability as compared with a 5F child catheter (15.0 cm [15.0 to 15.0] versus 13.0 cm [12.8 to 13.0], PϽ0.005). A total of 51 lesions, in which conventional techniques had been unsuccessful, were treated using the 4F mother-child technique. Lesion success was achieved in 48 (94%) lesions. Stent deployment was attempted in 44 (86%) and was successful in 40 of 44 (91%). There were 2 instances of stent dislodgment. Conclusions-With the superior trackability of the 4F child catheter and with increased backup support of the mother-child system, the 4F mother-child system provided Ͼ90% success rate for lesions in which conventional techniques had failed. The 4F mother-child system may become a viable alternative to conventional techniques in treating complex coronary lesions. (Circ Cardiovasc Interv. 2011;4:155-161.)
Transradial PCI for CTO may be feasible in noncomplex cases, although complex cases still pose a challenge. In cases of transradial PCI for CTO, if possible, guiding catheter size ≥7 F should be selected regardless of lesion morphology. Furthermore, the transfemoral approach should be preferentially considered for complex CTO, particularly in cases with calcification.
This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.