We have recently developed a simple algorithm for the classification of household and locomotive activities using the ratio of unfiltered to filtered synthetic acceleration (gravity-removal physical activity classification algorithm, GRPACA) measured by a triaxial accelerometer. The purpose of the present study was to develop a new model for the immediate estimation of daily physical activity intensities using a triaxial accelerometer. A total of sixty-six subjects were randomly assigned into validation (n 44) and cross-validation (n 22) groups. All subjects performed fourteen activities while wearing a triaxial accelerometer in a controlled laboratory setting. During each activity, energy expenditure was measured by indirect calorimetry, and physical activity intensities were expressed as metabolic equivalents (MET). The validation group displayed strong relationships between measured MET and filtered synthetic accelerations for household (r 0·907, P,0·001) and locomotive (r 0·961, P, 0·001) activities. In the cross-validation group, two GRPACA-based linear regression models provided highly accurate MET estimation for household and locomotive activities. Results were similar when equations were developed by non-linear regression or sex-specific linear or non-linear regressions. Sedentary activities were also accurately estimated by the specific linear regression classified from other activity counts. Therefore, the use of a triaxial accelerometer in combination with a GRPACA permits more accurate and immediate estimation of daily physical activity intensities, compared with previously reported cutoff classification models. This method may be useful for field investigations as well as for self-monitoring by general users.
These results suggest that at least 10 METs x h/w in aerobic exercise, such as brisk walking, light jogging or stationary ergometer usage, is required for visceral fat reduction, and that there is a dose-response relationship between aerobic exercise and visceral fat reduction in obese subjects without metabolic-related disorders.
Time spent playing one-third of the activities supplied by motion- and gesture-controlled video games can count toward the daily amount of exercise required according to the guidelines provided by the American College of Sports Medicine and the American Heart Association, which focus on 30 min of moderate-intensity daily physical activity 5 d x wk(-1).
Background Self-monitoring using certain types of pedometers and accelerometers has been reported to be effective for promoting and maintaining physical activity (PA). However, the validity of estimating the level of PA or PA energy expenditure (PAEE) for general consumers using wearable devices has not been sufficiently established. Objective We examined the validity of 12 wearable devices for determining PAEE during 1 standardized day in a metabolic chamber and 15 free-living days using the doubly labeled water (DLW) method. Methods A total of 19 healthy adults aged 21 to 50 years (9 men and 10 women) participated in this study. They followed a standardized PA protocol in a metabolic chamber for an entire day while simultaneously wearing 12 wearable devices: 5 devices on the waist, 5 on the wrist, and 2 placed in the pocket. In addition, they spent their daily lives wearing 12 wearable devices under free-living conditions while being subjected to the DLW method for 15 days. The PAEE criterion was calculated by subtracting the basal metabolic rate measured by the metabolic chamber and 0.1×total energy expenditure (TEE) from TEE. The TEE was obtained by the metabolic chamber and DLW methods. The PAEE values of wearable devices were also extracted or calculated from each mobile phone app or website. The Dunnett test and Pearson and Spearman correlation coefficients were used to examine the variables estimated by wearable devices. Results On the standardized day, the PAEE estimated using the metabolic chamber (PAEEcha) was 528.8±149.4 kcal/day. The PAEEs of all devices except the TANITA AM-160 (513.8±135.0 kcal/day; P>.05), SUZUKEN Lifecorder EX (519.3±89.3 kcal/day; P>.05), and Panasonic Actimarker (545.9±141.7 kcal/day; P>.05) were significantly different from the PAEEcha. None of the devices was correlated with PAEEcha according to both Pearson (r=−.13 to .37) and Spearman (ρ=−.25 to .46) correlation tests. During the 15 free-living days, the PAEE estimated by DLW (PAEEdlw) was 728.0±162.7 kcal/day. PAEE values of all devices except the Omron Active style Pro (716.2±159.0 kcal/day; P>.05) and Omron CaloriScan (707.5±172.7 kcal/day; P>.05) were significantly underestimated. Only 2 devices, the Omron Active style Pro (r=.46; P=.045) and Panasonic Actimarker (r=.48; P=.04), had significant positive correlations with PAEEdlw according to Pearson tests. In addition, 3 devices, the TANITA AM-160 (ρ=.50; P=.03), Omron CaloriScan (ρ=.48; P=.04), and Omron Active style Pro (ρ=.48; P=.04), could be ranked in PAEEdlw. Conclusions Most wearable devices do not provide comparable PAEE estimates when using gold standard methods during 1 standardized day or 15 free-living days. Continuous development and evaluations of these wearable devices are needed for better estimations of PAEE.
The aims of our study were to examine whether a gravity-removal physical activity classification algorithm (GRPACA) is applicable for discrimination between nonlocomotive and locomotive activities for various physical activities (PAs) of children and to prove that this approach improves the estimation accuracy of a prediction model for children using an accelerometer. Japanese children (42 boys and 26 girls) attending primary school were invited to participate in this study. We used a triaxial accelerometer with a sampling interval of 32 Hz and within a measurement range of ±6 G. Participants were asked to perform 6 nonlocomotive and 5 locomotive activities. We measured raw synthetic acceleration with the triaxial accelerometer and monitored oxygen consumption and carbon dioxide production during each activity with the Douglas bag method. In addition, the resting metabolic rate (RMR) was measured with the subject sitting on a chair to calculate metabolic equivalents (METs). When the ratio of unfiltered synthetic acceleration (USA) and filtered synthetic acceleration (FSA) was 1.12, the rate of correct discrimination between nonlocomotive and locomotive activities was excellent, at 99.1% on average. As a result, a strong linear relationship was found for both nonlocomotive (METs = 0.013×synthetic acceleration +1.220, R2 = 0.772) and locomotive (METs = 0.005×synthetic acceleration +0.944, R2 = 0.880) activities, except for climbing down and up. The mean differences between the values predicted by our model and measured METs were −0.50 to 0.23 for moderate to vigorous intensity (>3.5 METs) PAs like running, ball throwing and washing the floor, which were regarded as unpredictable PAs. In addition, the difference was within 0.25 METs for sedentary to mild moderate PAs (<3.5 METs). Our specific calibration model that discriminates between nonlocomotive and locomotive activities for children can be useful to evaluate the sedentary to vigorous PAs intensity of both nonlocomotive and locomotive activities.
Summary Many predictive equations for basal metabolic rate (BMR) based on anthropometric measurements, age, and sex have been developed, mainly for healthy Caucasians. However, it has been reported that many of these equations, used widely, overestimate BMR not only for Asians, but also for Caucasians. The present study examined the accuracy of several predictive equations for BMR in Japanese subjects. In 365 healthy Japanese male and female subjects, aged 18 to 79 y, BMR was measured in the post-absorptive state using a mask and Douglas bag. Six predictive equations were examined. Total error was used as an index of the accuracy of each equation's prediction. Predicted BMR values by Dietary Reference Intakes for Japanese (Japan-DRI), Adjusted Dietary Reference Intakes for Japanese (Adjusted-DRI), and Ganpule equations were not significantly different from the measured BMR in either sex. On the other hand, Harris-Benedict, Schofield, and Food and Agriculture Organization of the United Nations/World Health Organization/United Nations University equations were significantly higher than the measured BMR in both sexes. The prediction error by Japan-DRI, Adjusted-DRI, and Harris-Benedict equations was significantly correlated with body weight in both sexes. Total error using the Ganpule equation was low in both males and females (125 and 99 kcal/d, respectively). In addition, total error using the Adjusted-DRI equation was low in females (95 kcal/d). Thus, the Ganpule equation was the most accurate in predicting BMR in our healthy Japanese subjects, because the difference between the predicted and measured BMR was relatively small, and body weight had no effect on the prediction error.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.