Background
Currently, cryoballoon ablation (CBA) has proven to be highly effective in achieving free from atrial fibrillation (AF), especially paroxysmal AF. However, the optimal freezing protocol for each patient to achieve successful pulmonary vein isolation by only CBA is still uncertain. The aim of this study was to evaluate the clinical implications of a reduction in the freezing duration (<180s) during CBA guided by the time to target temperature.
Methods
From November 2015 to August 2018, 286 consecutive paroxysmal AF patients undergoing CBA were enrolled. We compared 107 patients undergoing a tailor-made CBA procedure (Group A; August 2017-August 2018) to 179 patients with a standard CBA procedure (Group B; November 2015–July 2017). In Group A, the freezing duration was reduced to 150s when the temperature reached ≤−40°C within 40s. Furthermore, we reduced it to 120s when it reached ≤−50°C within 60s. In the other patients, the freezing time was 180s except for excessive freezing over −60°C and/or emergent situations while monitoring the esophageal temperature and for phrenic nerve injury as in Group B.
Results
The baseline clinical characteristics were similar between two groups. In Group A, 89 patients (83%) underwent CBA with a reduction in the freezing time. The rate of having reduction time in left inferior PV (LIPV) and right inferior PV (RIPV) was lower compared with left superior PV (LSPV) and right superior PV (RSPV) (respectively 17%, 29%, 56%, and 63.5%). However, for right inferior PV, in 31 patients having the reduced freezing time, none of them required touch-up ablation. Although the procedure time and frequency of touch-up ablation did not differ between the 2 groups, total freezing time for each PV was significantly shorter in Group A than Group B as shown in figure (LSPV: 164±28s vs. 216±67s; p<0.001, LIPV: 187±44s vs. 218±69s; p<0.001, RSPV: 147±31s vs. 192±51s; p<0.001, RIPV: 180±50 vs. 218±73s; p<0.001). The AF free survival rate during the follow-up period (356±167 days) was similar between the 2 groups (log-rank test, p=0.38). Furthermore, the complication rate was similar 2 groups.
The freezing time for each PV
Conclusion
The safety and efficacy of the new tailor-made CBA strategy were non-inferior to the standard procedure. This study showed that the unnecessary freezing time could be reduced in most of paroxysmal AF patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.