BackgroundDiabetic retinopathy (DR) is a leading cause of vision loss in adults. Currently, the standard imaging technique to monitor and prognosticate DR and diabetic maculopathy is dye-based angiography. With the introduction of optical coherence tomography angiography (OCTA), it may serve as a potential rapid, non-invasive imaging modality as an adjunct.Main textRecent studies on the role of OCTA in DR include the use of vascular parameters e.g., vessel density, intercapillary spacing, vessel diameter index, length of vessels based on skeletonised OCTA, the total length of vessels, vascular architecture and area of the foveal avascular zone. These quantitative measures may be able to detect changes with the severity and progress of DR for clinical research. OCTA may also serve as a non-invasive imaging method to detect diabetic macula ischemia, which may help predict visual prognosis. However, there are many limitations of OCTA in DR, such as difficulty in segmentation between superficial and deep capillary plexus; and its use in diabetic macula edema where the presence of cystic spaces may affect image results. Future applications of OCTA in the anterior segment include detection of anterior segment ischemia and iris neovascularisation associated with proliferative DR and risk of neovascular glaucoma.ConclusionOCTA may potentially serve as a useful non-invasive imaging tool in the diagnosis and monitoring of diabetic retinopathy and maculopathy in the future. Future studies may demonstrate how quantitative OCTA measures may have a role in detecting early retinal changes in patients with diabetes.
We investigated the characteristics of the choriocapillaris flow voids using optical coherence tomography angiography (OCTA) in 85 patients (164 eyes) with hypertension (mean ± SD age, 56 ± 11 years; 45% women; 20% poorly controlled BP; 16% diabetes) who are without ocular diseases and determined possible correlations with systemic vascular risk factors. Data on 24-hour ambulatory blood pressure (BP), serum creatinine, and urine microalbumin/creatinine ratio (MCR) were collected. Estimated glomerular filtration rate (eGFR) was calculated based on CKD-EPI Creatinine Equation. OCTA imaging (6 × 6 mm scans; AngioVue) with quantitative microvascular analysis of the choriocapillaris was performed. Linear regression was used to investigate the association of systemic risk factors with area (percentage), size (pixels) and number of choriocapillaris flow voids. Diabetes (β = 0.33; 95% CI, 0.02 to 0.63) and daytime systolic BP (β = −0.13; 95% CI, −0.24 to −0.02) were associated with areas of flow voids. Age (β = 0.21; 95% CI, 0.06 to 0.36) and daytime diastolic BP (β = −0.18; 95% CI, −0.34 to −0.02) were associated with size of flow voids. Age (β = −21.21; 95% CI, −31.79 to −10.63) and nighttime diastolic BP (β = 13.89; 95% CI, 0.61 to 27.17) were associated with number of flow voids. Kidney parameters were not associated with any features of flow voids. In patients with hypertension, a higher BP appeared to increase blood flow in the choriocapillaris which needs to be considered when using the OCTA to study eye diseases in hypertensives.
Corneal neovascularization (CoNV) could be treated by novel anti-angiogenic therapies, though reliable and objective imaging tools to evaluate corneal vasculature and treatment efficacy is still lacking. Optical coherence tomography angiography (OCTA) –currently designed as a retinal vascular imaging system— has been recently adapted for anterior-segment and showed good potential for successful imaging of CoNV. However, further development requires an animal model where parameters can be studied more carefully with histological comparison. Our study evaluated the OCTA in suture-induced CoNV in a rabbit model compared to indocyanine green angiography (ICGA) and slit-lamp photography (SLP). Overall vessel density measurements from OCTA showed good correlation with ICGA (0.957) and SLP (0.992). Vessels density by OCTA was higher than ICGA and SLP (mean = 20.77 ± 9.8%, 15.71 ± 6.28% and 17.55 ± 8.36%, respectively, P < 0.05). OCTA was able to depict CoNV similarly to SLP and ICGA, though it could better detect small vessels. Moreover, the depth and growth of vessels could be assessed using en-face and serial-scans. This study validated the OCTA in a rabbit model as a useful imaging tool for translational studies on CoNV. This may contribute to further studies on OCTA for anterior-segment including serial evaluation of emerging anti-angiogenic therapies.
In this pilot clinical study, we describe successful delineation of corneal vessels with substantial image quality using a new SD OCTA system. The vessel density measurements were greater using the SSADA compared with SD OCTA system in the same area of corneal vascularisation. Further studies are required to confirm the advantages, limitations and differences between these OCTA systems for the anterior segment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.