In this paper, we present a systematic procedure to design a solar simulator for hightemperature concentrated solar thermal and thermochemical research. The 45 kW¡, simulator consists of seven identical radiation units of common focus, each comprised of a 6.5 kWg xenon arc lamp close-coupled to a precision reßector in the shape of a truncated ellipsoid. The size and shape of each reflector is optimized by a Monte Carlo ray tracing analysis to achieve multiple design objectives, including high transfer efficiency of radiation from the lamps to the common focal plane and desired flux distribution. Based on the numerical results, the final optimized design will deliver 7.5 kW over a 6 cm diameter circular disk located in the focal plane, with a peak flux approaching 3.7 MWIm^.
The University of Minnesota's high flux simulator delivers radiative power of approximately 9.2 kW over a Ø60 mm circular area located in the focal plane, corresponding to an average flux of 3200 kW m−2, with a peak flux of 7300 kW m−2.
This paper presents measured performance of the University of Minnesota’s 45 kWe indoor high-flux solar simulator. The simulator consists of seven radiation units, each comprised of a 6.5 kWe xenon short arc lamp coupled to a reflector in the shape of a truncated ellipsoid of revolution. Data include flux distribution at the focal plane for all seven radiation units operating in tandem and for individual radiation units. The flux distribution is measured optically by acquiring the image of radiation reflected from a Lambertian target with a CCD camera equipped with neutral density optical filters. The CCD camera output is calibrated to irradiation using a circular foil heat flux gage. It is shown that accurate calibration of the heat flux gage must account for its response to the spectral characteristics of the radiation source. The simulator delivers radiative power of approximately 9.2 kW over a 60-mm diameter circular area located in the focal plane, corresponding to an average flux of 3.2 MW m−2, with a peak flux of 7.3 MW m−2.
In this paper, we present a systematic procedure to design a solar simulator for high-temperature concentrated solar thermal and thermo-chemical research. The 45 kWe simulator consists of seven identical radiation units of common focus, each comprised of a 6.5 kWe xenon arc lamp close-coupled to a precision reflector in the shape of a truncated ellipsoid. The size and shape of each reflector is optimized by a Monte Carlo ray tracing analysis to achieve multiple design objectives, including high transfer efficiency of radiation from the lamps to the common focal plane and desired flux distribution. Based on the numerical results, the final optimized design will deliver 7.5 kW over a 6-cm diameter circular disc located in the focal plane, with a peak flux approaching 3.7 MW/m2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.