Brown and Caldwell designed a stationary sludge suction header as part of a retrofit of 3 of 24 rectangular final settling tanks, or clarifiers, for demonstration at the Metropolitan Wastewater Treatment Plant (Metro) in St. Paul, Minnesota. The sludge suction header replaced a cross collector system that contributed to re-suspension of settled solids and the formation of transverse currents. The retrofit was completed in December 1996 at a cost of only $115,000 per clarifier.During the following year, Metro operators conducted a supplemental sampling program, consisting of sludge settling, flocculation, and compaction testing, that would provide the basis for a performance comparison between modified and unmodified clarifiers. Improved effluent quality of the modified over the unmodified clarifiers was evident. Statistical analysis of sludge characterization data linked improved performance to the new sludge suction header. Based on these results, the remaining 21 final clarifiers at Metro will be identically retrofitted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.