Objective To develop and apply an implanted neuroprosthesis to restore arm and hand function to individuals with high level tetraplegia Design Case study. Setting Clinical research laboratory. Participants Two individuals with spinal cord injuries at or above the C4 motor level. Interventions The individuals were each implanted with two stimulators (24 stimulation channels and 4 myoelectric recording channels total). Stimulating electrodes were placed in the shoulder and arm, including the first chronic application of spiral nerve cuff electrodes to activate a human limb. Myoelectric recording electrodes were placed in the head and neck areas. Main Outcome Measures The successful installation and operation of the neuroprosthesis, along with the electrode performance, range of motion, grasp strength, joint moments, and performance in activities of daily living. Results The neuroprosthesis system was successfully implanted in both individuals. Spiral nerve cuff electrodes were placed around upper extremity nerves and activated the intended muscles. In both individuals, the neuroprosthesis has functioned properly for at least 2.5 years post-implant. Hand, wrist, forearm, elbow and shoulder movements were achieved. A mobile arm support was needed to support the mass of the arm during functional activities. One individual was able to perform several activities of daily living with some limitations due to spasticity. The second individual was able to partially complete two activities of daily living. Conclusions Functional electrical stimulation is a feasible intervention for restoring arm and hand functions to individuals with high tetraplegia. Forces and movements were generated at the hand, wrist, elbow and shoulder that allowed the performance of activities of daily living, with some limitations requiring the use of a mobile arm support to assist the stimulated shoulder forces.
In humans, we tested the hypothesis that a flat interface nerve electrode (FINE) placed around the femoral nerve trunk can selectively stimulate each muscle the nerve innervates. In a series of intraoperative trials during routine vascular surgeries, an eight-contact FINE was placed around the femoral nerve between the inguinal ligament and the first nerve branching point. The capability of the FINE to selectively recruit muscles innervated by the femoral nerve was assessed with electromyograms (EMGs) of the twitch responses to electrical stimulation. At least four of the six muscles innervated by the femoral nerve were independently and selectively recruited in all subjects. Of these, at least one muscle was a hip flexor and at least two were knee extensors. Results from the intraoperative experiments were used to estimate the potential for the electrode to restore knee extension and hip flexion through functional electrical stimulation. Normalized EMGs and biomechanical simulations were used to estimate joint moments and functional efficacy. Estimated knee extension moments exceed the threshold required for the sit-to-stand transition.
Surface electrical stimulation has the potential to be a powerful and non-invasive treatment for a variety of medical conditions but currently it is difficult to obtain consistent evoked responses. A viable clinical system must be able to adapt to variations in individuals to produce repeatable results. To more fully study the effect of these variations without performing exhaustive testing on human subjects, a system of computer models was created to predict motor and sensory axon activation in the median nerve due to surface electrical stimulation at the elbow. An anatomically-based finite element model of the arm was built to accurately predict voltages resulting from surface electrical stimulation. In addition, two axon models were developed based on previously published models to incorporate physiological differences between sensory and motor axons. This resulted in axon models that could reproduce experimental results for conduction velocity, strength-duration curves and activation threshold. Differences in experimentally obtained action potential shape between the motor and sensory axons were reflected in the models. The models predicted a lower threshold for sensory axons than motor axons of the same diameter, allowing a range of sensory axons to be activated before any motor axons. This system of models will be a useful tool for development of surface electrical stimulation as a method to target specific neural functions.
Nine spiral nerve cuff electrodes were implanted in two human subjects for up to three years with no adverse functional effects. The objective of this study was to look at the long term nerve and muscle response to stimulation through nerve cuff electrodes. The nerve conduction velocity remained within the clinically accepted range for the entire testing period. The stimulation thresholds stabilized after approximately 20 weeks. The variability in the activation over time was not different from muscle-based electrodes used in implanted functional electrical stimulation systems. Three electrodes had multiple, independent contacts to evaluate selective recruitment of muscles. A single muscle could be selectively activated from each electrode using single-contact stimulation and the selectivity was increased with the use of field steering techniques. The selectivity after three years was consistent with selectivity measured during the implant surgery. Nerve cuff electrodes are effective for chronic muscle activation and multichannel functional electrical stimulation in humans.
Testing of the recruitment properties and selective activation capabilities of a multi-contact spiral nerve cuff electrode was performed intraoperatively in 21 human subjects. The study was conducted in two phases. An exploratory phase with ten subjects gave a preliminary overview of the data and data collection process and a systematic phase with eleven subjects provided detailed recruitment properties. The mean stimulation threshold of 25 +/- 17 nC was not significantly different than previous studies in animal models but much lower than muscle electrodes. The selectivity, defined as the percent of total activation of the first muscle recruited before another muscle reached threshold, ranged from 27% to 97% with a mean of 55%. In each case, the muscle that was selectively activated was the first muscle to branch distal to the cuff location. This study serves as a preliminary evaluation of nerve cuff electrodes in humans prior to chronic implant in subjects with high tetraplegia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.