Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a well-established first-line invasive modality for mediastinal lymph node staging in lung cancer patients and in the diagnostic workup of patients with mediastinal adenopathy. With the current 21- and 22-gauge (G) EBUS-TBNA needles, the procedure can be limited by the degree of flexibility in the needle and the size of the lumen in tissue acquisition. Objective: We report our initial experience with a first-generation flexible 19-G EBUS-TBNA (Flex 19G; Olympus Respiratory America, Redmond, WA, USA) needle with regards to efficacy and safety. Methods: The Flex 19G EBUS-TBNA needle was used in 47 selected patients with enlarged hilar and/or mediastinal lymphadenopathy at 3 centers. The standard Olympus EBUS scope with a 2.2-mm working channel was used in all cases. Results: The diagnostic yield of the Flex 19G needle according to clinical cytopathology reports was 89% (42/47). The diagnosis and their respective diagnostic yield with the Flex 19G EBUS-TBNA needle were malignancy 24/27 (89%), sarcoidosis 13/14 (93%), and reactive lymph node hyperplasia 5/6 (83%). The mean short axis of the sampled lymph nodes was 19 ± 9 mm. No complications occurred except for 1 instance of moderate bleeding, which did not require intervention beyond suctioning and subsequently resolved. All 13 patients diagnosed with adenocarcinoma by the 19-G needle had sufficient tissue for genetic testing. Conclusion: EBUS-TBNA using the first-generation Flex 19G needle is feasible and safe with promising diagnostic yield while providing a greater degree of flexion with the Olympus EBUS scope. Additional clinical evaluations are warranted.
Most patients treated with high-frequency oscillation have acute respiratory distress syndrome and severe hypoxemia that modestly improves 2 hrs after high-frequency oscillation application. However, oxygenation worsens in some patients, complications are common, and mortality is high.
Background: Although many studies have assessed the diagnostic utility of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in the context of a specific disease, few studies have assessed the overall diagnostic yield, sensitivity, and negative predictive value in patients with isolated mediastinal and hilar lymphadenopathy (IMHL). Objective: We evaluated the performance of EBUS-TBNA for diagnosing IMHL in a population with a high prevalence of concurrent or preexisting non-pulmonary malignancy. Methods: A retrospective chart review of patients who underwent EBUS-TBNA from October 2008 to April 2014 was performed to identify patients with IMHL. Patients with known or suspected primary pulmonary malignancy were excluded. When available, EBUS-TBNA results were cross-referenced with further diagnostic investigation or clinical diagnosis based on follow-up. Results: EBUS-TBNA was used to sample 765 lymph nodes from 350 patients. One hundred and fourteen (33.3%) patients had a concurrent or preexisting non-pulmonary malignancy. The overall yield of EBUS-TBNA for specific diagnosis was 300/350 (86%). The diagnostic yield for sarcoidosis, lymphoproliferative disease, metastatic lymphadenopathy from extrathoracic malignancy, and necrotizing granuloma was 123/149 (83%), 27/33 (82%), 20/25 (80%), and 13/19 (68%), respectively. Amongst 50 patients with non-diagnostic EBUS-TBNA, 25 yielded an insufficient sample and another 25 yielded only benign lymphoid material which was not representative of the underlying pathology. Overall, EBUS-TBNA had a sensitivity of 89%, a diagnostic yield of 86%, and a negative predictive value of 79%. Conclusion: For patients with isolated hilar or mediastinal lymphadenopathy and a high background prevalence of concurrent and preexisting non-pulmonary malignancy, EBUS-TBNA is a reliable first-line diagnostic investigation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.