Background Oxidative stress is a disruption of the pro-oxidative-antioxidant balance, caused by excessive production or ineffective removal of reactive oxygen species. Material/Methods The study included 42 male patients aged 38 to 69 years. The first group consisted of 21 men with osteoarthritis after primary hip arthroplasty using the Smith & Nephew Birmingham Hip Resurfacing implant. The second group included 21 men after hip arthroplasty using the femoral neck SPIRON K-implant. In both groups, concentrations of ions, the antioxidant system in the blood, and parameters of oxidative stress were evaluated twice. Clinical assessment using the Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, and Short Form (12) Health Survey (SF-12) scales was performed. Results Concentrations of metal ions in the blood and the level of oxidative stress were significantly higher in the resurfacing group than in the femoral neck arthroplasty group. The response of the antioxidant system was significantly greater in the femoral neck arthroplasty group. During clinical evaluation, groups did not show significant differences, with the exception of greater shortening of the operated limb and a lower score in the mental-sphere of the SF-12 scale in the resurfacing arthroplasty group. Conclusions Resurfacing hip arthroplasty increased oxidative stress, increased the concentration of metal ions, and did not affect alignment of the abbreviation of the operated limb. A significant improvement in the quality of life of patients in the mental sphere according to the SF-12 occurred after the application of resurfacing arthroplasty, in the first month after the procedure.
Computed tomography is a modern technique producing high quality image of scanned organs. It plays a significant role in diagnostic work-up on orthopedics wards. This paper presents an analysis of management of two cases of Hawkins type I talar neck fracture with ankle joint rotation. In both patients, the diagnosis was based on conventional radiographs of the ankle joint in two projections and was subsequently verified with CT scans. The findings of a CT scan of the talus had a significant impact on further treatment and physiotherapy. Non-surgical treatment consisting in immobilization with a short leg cast combined with medication and magnetic field therapy produced a positive therapeutic outcome. A follow-up CT scan of the talus revealed bone union with remodelling in both patients. The functional outcome according to the AOFAS scale should be regarded good. Computed tomography is the radiological modality for detecting talar neck fractures and determining the presence of displacement. Follow-up CT scans evaluate the natural process of bone healing, which is crucial for treatment decisions regarding weight-bearing status. A correct diagnosis based on CT helps to prevent the development of necrosis and posttraumatic (secondary) degenerative changes as well as advanced physical disability, especially among youn-ger patients, in whom the injury is most common, consequently helping to avoid a long and costly treatment.
Surface arthroplasty, also referred to as resurfacing, is a method of sparing hip arthroplasty, which is a surgical alternative usually reserved for younger, active patients. The introduction of successive generations of implants with metal-on-metal articulation resulted in increased interest in this method of treatment. Despite the unquestionable advantages and promising initial results, resurfacing has some limitations and disadvantages. One of them is the increase in the concentration of metal ions. Although they are necessary for the proper functioning of the human body, in large amounts they can lead to serious reactions of the soft tissues adjacent to the prosthesis, including metallosis, ALVAL (Aseptic Lyphocytic Vasculitis-Associated Lesion), or the formation of pseudotumours. Despite numerous studies and scientific reports, there is a need for further work on the relationship between the concentration levels of metal ions in people after resurfacing and the biological, causal mechanisms of the development of adverse reactions in the body.
Rationale: Resurfacing arthroplasty using the J&J DePuy ASR system was withdrawn from surgical treatment due to the necessity of frequent revision procedures after its application. There have been many studies concerning treatment of acetabular bone loss using different operating techniques. However, we felt that data of custom - made implant usage in such cases is highly insufficient, and there is lack of evidence on its application in treatment of loosening of the previous implant. The aim of the study was to evaluate the effectiveness of surgical treatment with a custom-made implant in a patient with extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&J DePuy ASR surface prosthesis in the early period of observation. Patient concerns: A 74-year-old patient was taken to the Orthopaedic Trauma Emergency Room due to increasing pain in the right hip for about 3 months. Nine years earlier he underwent resurfacing arthroplasty of the right hip using the J&J DePuy ASR method. Diagnoses: The imaging diagnostics (X-ray, computed tomography, ultrasound) revealed the presence of a pseudotumor and lysis around the acetabular implant, which caused a fracture in the acetabulum. Interventions: Revision arthroplasty of the right hip joint was performed with the removal of the ASR implant. During the procedure extensive bone defects were visualized, preventing the insertion of the revision acetabulum. After extensive plasticization of the defects with the use of allogeneic cancellous chips the “hanging hip” was left with the intention of making another attempt to insert the implant after the reconstitution of the acetabular bone. A computed tomography examination 2.5 years after the ASR removal revealed the lack of an adequate degree of bone remodeling for the planned implant. Arthroplasty using custom - made aMace Acetabular Revision System by Materialize was performed 3 years after the removal of ASR. Outcomes: Optimal implant adherence to the bone base and full osseointegration with the pelvic bone bearing has been achieved. Significant improvement in clinical parameters has been noted, with no complications in the postoperative period. Lessons: The use of an individual custom-made implant in extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&J DePuy ASR surface prosthesis in patients is an effective method of surgical treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.