: The persistence of Giardia, Cryptosporidium, Rotavirus, and Adenovirus in samples of raw and treated sewage collected monthly in 2010 at the Biological Wastewater Treatment Plant of Ribeirão Preto, SP, Brazil, was analyzed. The USEPA Method 1623 was used to detect and quantify Giardia and Cryptosporidium. An enzyme immunoassay was carried out to test Rotavirus and Adenovirus antigen optical density (Rotascreen® and Adenoscreen®). The results show a significant decrease in the concentrations of Giardia, Rotavirus and Adenovirus (P < 0.05) and a trend of decreasing Cryptosporidium densities, without statistical significance. Giardia concentrations ranged from 120 to 2,200 cysts/L in raw sewage and from 0.45 to 3.5 cysts/L in treated sewage. Cryptosporidium concentration ranged from undetectable to 28.9 oocysts/L in raw sewage and undetectable to 1.05 oocysts/L in treated sewage. Rotavirus presented absorbance values that ranged from 1.17 ± 0.81 in raw sewage to 0.46 ± 0.32 in treated sewage. Adenovirus, in turn, presented absorbance values of 0.64 ± 0.20 in raw sewage and of 0.45 ± 0.04 in treated sewage. There was no significant seasonal tendency observed in the distribution of protozoa (oo)cysts and in the viral antigen density in the monthly sewage samples during 2010 (P > 0.05). Even though these pathogenic agents decreased after treatment, the remaining loads observed in treated sewage can reach the watercourses receiving it. Giardia, Cryptosporidium, Rotavirus, and Adenovirus are pathogens with very low infectious doses, representing a public health risk especially for vulnerable groups, such as children living near these watercourses and homeless people using this water for various purposes. Studies addressing the environmental persistence of opportunistic pathogens in watercourses are hugely important in the public health sphere, especially in developing countries, where economic, social, cultural, and environmental factors still persist that are favorable to population's exposure to diarrhea-causing agents.
Latin America, Africa, and Asia present wide dissemination and high prevalence rates of waterborne parasitic diseases, which is a strong indicative of the fragility of public sanitation systems. In this context, parasitological analyses represent extremely relevant instruments. Several parasite diagnosis methods exist, among which Ritchie's method (1948) stands out. This method uses formaldehyde and ether, two reagents of toxicological importance that can cause damages to environmental and occupational health. The present study aimed to compare Ritchie's method modified by Régis Anécimo, without use of solvents, with the traditional Ritchie's method, routinely used for helminth and protozoa diagnosing in Brazil. Some changes were introduced in the modified method, such as controlled increase of water temperature used after stool dilution and substitution of formaldehyde and ether by a neutral detergent before material centrifugation for observation of parasites. In examined samples by both methods, multiple infections were commonly observed; the modified method presented a similar sensitivity to identify the parasites. The development of analytic diagnosis methods that minimize the use of chemical products like ether and formaldehyde represents an important tool to prevent occupational diseases among exposed professionals, as well as to preserve environmental quality through the use of clean techniques.
The purpose of this study was to evaluate the behavior of metals, pathogen parasites, and indicator bacteria in sewage effluents during biological treatment by activated sludge in a wastewater treatment plant in Ribeirão Preto (WTP-RP), Sao Paulo, Brazil. The evaluation was done during a period of 1 year. Results showed that metal concentrations in treated effluents decreased, reaching concentrations according to those established by national regulations. The activated sludge process at the WTP-RP promoted a partial removal of parasites considered as possible indicators according to the WHO guidelines. Reduction factors varied between 18.2% and 100% for agents such as Endolimax nana, Entamoeba coli, Entamoeba hystolitica, Giardia sp., Ancylostoma sp., Ascaris sp., Fasciola hepatica, and Strongyloides stercoralis. A removal was also observed in total and fecal coliforms quantification. The present study represents an initial evaluation of the chemical and microbiological removal capacity of the WTP-RP. The results should be of interest for the authorities responsible for the environmental health at municipal, regional, national, and international levels.
This study aimed to evaluate the viability of using treated residuary water from the Biological Wastewater Treatment Plant of Ribeirão Preto to grow vegetables, through the characterization and quantification of parasites, coliforms, and heavy metals. Three equal cultivation areas were prepared. The first was irrigated with treated/chlorinated (0.2 mg L(-1)) wastewater, the second one with treated wastewater without chlorination, and the third site with potable water, which was the control group. The presence of Hymenolepis nana, Enterobius vermicularis, nematode larvae, and Entamoeba coli was verified in lettuce (Lactuca sativa) samples. Although nematode larvae were observed in rocket salad (Eruca sativa L.), no significant differences were found between the number of parasites and type of irrigation water used. No significant differences were found between the number of fecal coliforms in vegetables and the different types of irrigation. However, the vegetables irrigated with treated effluent without chlorination showed higher levels of fecal coliforms. The risk of pathogens is reduced with bleach addition to the treated effluent at 0.2 mg/L. Concentration of heavy metals in vegetables does not mean significant risks to human health, according with the parameters recommended by the World Health Organization.
High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.
Introduction: Storage tanks for household water usage guarantees convenience and safety forconsumers in relation to water intermittency. Neglecting a minimal care for storage tanks can turnthem into a source of water unfit for consumption. Objective: Evaluate the physical, chemical, andmicrobiological quality of water in household tanks to highlight the need for individual actions toguarantee the quality of water consumed at home. Methods: Residents of 217 homes answereda questionnaire to gather information about the water storage tank conditions and maintenance.Chlorine dosing, pH and temperature measurements were performed in situ and metal analyseswere made using an inductively coupled plasma mass spectrometry (ICP-MS). The presence ofparasites was evaluated using the spontaneous sedimentation technique and presence of bacteriafrom the coliform groups (total and fecal) were made using the multiple-tube technique with thechromogenic substrate. Results: Results showed that 115 participants knew the correct storage tankmaintenance period and 109 participants did not perform the storage tank maintenance at therecommended frequency. Mean values of chlorine, pH, and temperature were 1.34 mg/L, 6.5, and25.4 ºC, respectively. Average concentrations of metals were below the maximum values allowed.Parasites and bacteria were not detected. Tests indicated the water samples were in accordancewith the potable water quality standards endorsed or recommended by the Brazilian legislation.Conclusion: Results did not show microbiological contamination in study samples. Nevertheless, it isnecessary to keep the population regularly informed about the importance to maintain storage watertanks clean. Currently, there is a growing concern with the development of individual actions aimedat human health and prevention of water-related diseases concerning its access and use. Therefore,we need health education programs to guide community participation into the promotion of a betterquality of life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.