ObjectiveTo determine the diagnostic accuracy of point-of-care ultrasound in suspected pulmonary embolism.DesignSystematic review and meta-analysis.Data sourcesMEDLINE, Embase, CINAHL and Cochrane library were searched on 2 July 2020 with no restrictions on the date of publication. Subject headings or subheadings combined with text words for the concepts of pulmonary embolism, ultrasound and diagnosis were used.Eligibility criteria and data analysisEligible studies reported sensitivity and specificity of deep venous, lung, cardiac or multiorgan ultrasound in patients with suspected pulmonary embolism, using an adequate reference-test. Prospective, cross-sectional and retrospective studies were considered for eligibility. No restrictions were made on language. Studies were excluded if a control group consisted of healthy volunteers or if transesophageal or endobronchial ultrasound was used. Risk of bias was assessed using quality assessment of diagnostic accuracy studies-2. Meta-analysis of sensitivity and specificity was performed by construction of hierarchical summary receiver operator curves. I2 was used to assess the study heterogeneity.Main outcome measuresThe primary outcome was overall sensitivity and specificity of reported ultrasound signs, stratified by organ approach (deep venous, lung, cardiac and multiorgan). Secondary outcomes were stratum-specific sensitivity and specificity within subgroups defined by pretest probability of pulmonary embolism.Results6378 references were identified, and 70 studies included. The study population comprised 9664 patients with a prevalence of pulmonary embolism of 39.9% (3852/9664). Risk of bias in at least one domain was found in 98.6% (69/70) of included studies. Most frequently, 72.8% (51/70) of studies reported >24 hours between ultrasound examination and reference test or did not disclose time interval at all. Level of heterogeneity ranged from 0% to 100%. Most notable ultrasound signs were bilateral compression of femoral and popliteal veins (22 studies; 4708 patients; sensitivity 43.7% (36.3% to 51.4%); specificity 96.7% (95.4% to 97.6%)), presence of at least one hypoechoic pleural-based lesion (19 studies; 2134 patients; sensitivity 81.4% (73.2% to 87.5%); specificity 87.4% (80.9% to 91.9%)), D-sign (13 studies; 1579 patients; sensitivity 29.7% (24.6% to 35.4%); specificity 96.2% (93.1% to 98.0%)), visible right ventricular thrombus (5 studies; 995 patients; sensitivity 4.7% (2.7% to 8.1%); specificity 100% (99.0% to 100%)) and McConnell’s sign (11 studies; 1480 patients; sensitivity 29.1% (20.0% to 40.1%); specificity 98.6% (96.7% to 99.4%)).ConclusionSeveral ultrasound signs exhibit a high specificity for pulmonary embolism, suggesting that implementation of ultrasound in the initial assessment of patients with suspected pulmonary embolism may improve the selection of patients for radiation imaging.PROSPERO registration numberCRD42020184313.
ObjectiveTo determine the diagnostic accuracy of point-of-care ultrasound in suspected pulmonary embolism. DesignSystematic review and meta-analysis.Data sources MEDLINE, Embase, CINAHL, and Cochrane library was searched on the 2 nd of July, 2020 with no restrictions on date of publication. Subject headings or subheadings combined with text words for the concepts of pulmonary embolism, ultrasound, and diagnosis were used. Eligibility criteria and data analysisEligible studies reported sensitivity and specificity of deep venous, lung, cardiac, or multiorgan ultrasound in patients with suspected pulmonary embolism, using an adequate reference-test. Prospective, crosssectional and retrospective studies were considered for eligibility. No restrictions were made on language. Studies were excluded if a control group consisted of healthy volunteers or if transesophageal or endobronchial ultrasound was utilized. Risk of bias was assessed using quality assessment of diagnostic accuracy studies 2 (QUADAS-2). Meta-analysis of sensitivity and specificity was performed by construction of hierarchical summary receiver operator curves. I 2 was used to assess study heterogeneity. Main outcome measuresThe primary outcome was overall sensitivity and specificity of reported ultrasound signs, stratified by organ approach (deep venous, lung, cardiac, and multiorgan). Secondary outcomes were stratum specific sensitivity and specificity within subgroups defined by pretest probability of pulmonary embolism. Results6378 references were identified, and 70 studies included. The study population comprised 9664 patients with a prevalence of pulmonary embolism of 39.9% (3852/9664). Risk of bias in at least one domain was found in 98.6% (69/70) of included studies. Most frequently, 72.8% (51/70) of studies reported more than 24 hours between ultrasound examination and reference test or did not disclose time interval at all. Level of heterogeneity ranged from 0% to 100%. Most notable ultrasound signs were bilateral compression of femoral and popliteal veins (22 studies; 4708 patients; sensitivity 43.7% (36.3% to 51.4%); specificity 96.7% (95.4% to 97.6%), presence of at least one hypoechoic pleural based lesion (19 studies; 2,134 patients; sensitivity 81.4% (73.2% to 87.5%); specificity 87.4% (80.9% to 91.9%)), D-sign (13 studies; 1,579 patients; sensitivity 29.7% (24.6% to 35.4%); specificity 96.2% (93.1% to 98.0%)), visible right ventricular thrombus (5 studies; 995 patients; sensitivity 4.7% (2.7% to 8.1%); specificity 100% (99.0% to 100%)), and McConnell's sign (11 studies; 1,480 patients; sensitivity 29.1% (20.0% to 40.1%); specificity 98.6% (96.7% to 99.4%)). ConclusionSeveral ultrasound signs exhibit a high specificity for pulmonary embolism, suggesting that implementation of ultrasound in the initial assessment of patients with suspected pulmonary embolism may improve the selection of patients for radiation imaging. Study registration: PROSPERO CRD42020184313. Data extraction and quality assessmentTwo reviewers (CF and NJ) used a predes...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.