Abstract. Typical radiation portal monitor systems, RPM, deployed to detect illicit trafficking of radioactive materials include a set of gamma-ray detectors and neutron detectors. Measurements and models were made, and both detectors were compared. The importance of the distance with respect to the ground was studied. The response with a 252 Cf moderated neutron source (0.5 cm lead and 2.5 cm polyethylene) was calculated in order to compare with other studied alternatives in the USA by Pacific National Northwest Laboratory, PNNL. With these results we conclude that neutron detectors using 10 B+ZnS(Ag) are an interesting alternative for replacing 3 He detectors. From the analysis with MCNPX we propose an improvement in the detector design.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.