Two-color (800 and 400 nm) short (45 fs) linearly polarized pulses are used to ionize and dissociate D2 into a neutral deuterium atom and a deuteron. The yields and energies of the ions are measured left and right along the polarization vector. As the relative phase of the two colors is varied, strong yield asymmetries are found in the ion-energy regions traditionally identified as bond softening, above-threshold dissociation and rescattering. The asymmetries in these regions are quite different. A model based on the dynamic coupling by the laser field of the gerade and ungerade states in the molecular ion accounts for many of the observed features.
We demonstrate an experimental control of electron localization in deuterium molecular ions created and dissociated by the combined action of an attosecond pulse train and a many-cycle infrared (IR) pulse. The attosecond pulse train is synthesized using both even and odd high order harmonics of the driving IR frequency so that it can strobe the IR field once per IR cycle. An asymmetric ejection of the deuterium ions oscillates with the full IR period when the APT-IR time-delay is scanned. The observed control is due to the creation of a coherent superposition of 1s sigma{g} and 2p sigma{u} states via interference between one-photon and two-photon dissociation channels.
Abstract:We have designed and fabricated a 4 mm diameter rigid endoscopic probe to obtain high resolution micro-optical coherence tomography (µOCT) images from the tracheal epithelium of living swine. Our common-path fiber-optic probe used gradient-index focusing optics, a selectively coated prism reflector to implement a circular-obscuration apodization for depth-of-focus enhancement, and a common-path reference arm and an ultra-broadbrand supercontinuum laser to achieve high axial resolution. Benchtop characterization demonstrated lateral and axial resolutions of 3.4 μm and 1.7 μm, respectively (in tissue). Mechanical standoff rails flanking the imaging window allowed the epithelial surface to be maintained in focus without disrupting mucus flow. During in vivo imaging, relative motion was mitigated by inflating an airway balloon to hold the standoff rails on the epithelium. Software implemented image stabilization was also implemented during post-processing. The resulting image sequences yielded co-registered quantitative outputs of airway surface liquid and periciliary liquid layer thicknesses, ciliary beat frequency, and mucociliary transport rate, metrics that directly indicate airway epithelial function that have dominated in vitro research in diseases such as cystic fibrosis, but have not been available in vivo.
We verify numerically the phenomenon of logical stochastic resonance in a polarization bistable laser. Namely, we show that when one presents two weak binary inputs to the laser system, the response mirrors a logical OR(NOR) output. The reliability of the logic operation is dependent on the noise intensity. As one increases the noise, the probability of the output reflecting the desired OR(NOR) operation increases to nearly unity and then decreases. We also demonstrate that changing the bias morphs the output into another logic operation, AND(NAND), whose probability displays analogous behavior. Furthermore, we highlight the possibility of processing two logic gates in parallel in our laser system by exploiting two coupled orthogonal polarizations that can be detected simultaneously. This suggests that the computational power of the optical system may be enhanced by this additional potential for parallel processing.
We describe a dual, second harmonic generation (SHG) and third harmonic generation (THG) microscope, with the aim to obtain large-scale images of the cornea that can simultaneously resolve the micron-thick thin layers. We use an Ytterbium femtosecond laser as the laser source, the longer wavelength of which reduces scattering and allows simultaneous SHG and THG imaging. We measure one-dimensional SHG and THG profiles across the entire thickness of pig cornea, detected in both the forward and backward directions. These profiles allow us to clearly distinguish all the porcine corneal layers (epithelium, stroma, Descemet's membrane and endothelium). From these profiles, longitudinal cross sectional images of the corneal layers are generated, providing large scale topographic information with high-spatial resolution. The ability to obtain both SHG and THG signals in epi-detection on fresh eyes gives promising hopes for in vivo applications.
HiLo microscopy is a recently developed technique that provides both optical sectioning and fast imaging with a simple implementation and at a very low cost. The methodology combines widefield and speckled illumination images to obtain one optically sectioned image. Hence, the characteristics of such speckle illumination ultimately determine the quality of HiLo images and the overall performance of the method. In this work, we study how speckle contrast influence local variations of fluorescence intensity and brightness profiles of thick samples. We present this article as a guide to adjust the parameters of the system for optimizing the capabilities of this novel technology.
Optical coherence tomography (OCT) is an attractive medical modality due to its ability to acquire high-resolution, cross-sectional images inside the body using flexible, small-diameter, scanning fiber optic probes. Conventional, cross-sectional OCT imaging technologies have approximately 10-μm axial resolution and 30-μm lateral resolution, specifications that enable the visualization of microscopic architectural morphology. While this resolution is useful for many clinical applications, it is insufficient for resolving individual cells that characterize many diseases. To address this gap, a supercontinuum-laser-based, μm-resolution OCT (μOCT) system and a 500 μm-diameter, extended depth of focus single fiber optic probe for endoscopic and intravascular imaging were designed and fabricated. At the distal tip of the fiber optic probe, a cylindrical waveguide was used to divide the wavefront to provide multiple circular propagation modes. Once transmitted through a relatively high NA lens (NA >0.1), these modes were projected as multiple coaxial foci (~3 μm full width at half maximum (FWHM)) over a greatly extended focal depth range. The distal tip of the probe also contained a common-path reference reflectance to minimize polarization and dispersion imbalances between sample and reference arm light. Measurements showed that the probe provides a 20-fold depth of focus extension, maintaining a 3-5 µm lateral resolution (FWHM of PSF) and a 2 μm axial resolution over a depth range of approximately 1 mm. These results suggest that this new optical configuration will be useful for achieving high-resolution, cross-sectional OCT imaging in catheter/endoscope-based medical imaging devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.