Recent technological advances have expanded fluorescence (FL) imaging into the second near-infrared region (NIR-II; wavelength = 1000-1700 nm), providing high spatial resolution through deep tissues. However, bright and compact fluorophores are rare in this region, and sophisticated control over NIR-II probes has not been fully achieved yet. Herein, we report an enzyme-activatable NIR-II probe that exhibits FL upon matrix metalloprotease activity in tumor microenvironment. Bright and stable PbS/CdS/ZnS core/shell/shell quantum dots (QDs) were synthesized as a model NIR-II fluorophore, and activatable modulators were attached to exploit photoexcited electron transfer (PET) quenching. The quasi type-II QD band alignment allowed rapid and effective FL modulations with the compact surface ligand modulator that contains methylene blue PET quencher. The modulator was optimized to afford full enzyme accessibility and high activation signal surge upon the enzyme activity. Using a colon cancer mouse model, the probe demonstrated selective FL activation at tumor sites with 3-fold signal enhancement in 10 min. Optical phantom experiments confirmed the advantages of the NIR-II probe over conventional dyes in the first near-infrared region.
Potential advantages of quantum dot (QD) imaging in the second optical window (SOW) at 1,000 to 1,400 nm over the first optical window (FOW) at 700 to 900 nm have attracted much interest. QDs that emit at 800 nm (800QDs) and QDs that emit at 1,300 nm (1,300QDs) are used to investigate the imaging depths at the FOW and SOW. QD images in biologic tissues are processed binarized via global thresholding method, and the imaging depths are determined using the criteria of contrast to noise ratio and relative apparent size. Owing to the reduced scattering in the SOW, imaging depth in skin can be extended by approximately three times for 1,300QD/SOW over 800QD/FOW. In liver, excitation of 1,300QD/SOW can be shifted to longer wavelengths; thus, the imaging depth can be extended by 1.4 times. Effects of quantum yield (QY), concentration, incidence angle, polarization, and fluence rate F on imaging depth are comprehensively studied. Under F approved by the Food and Drug Administration, 1,300QDs with 50% QY can reach imaging depths of 29.7 mm in liver and 17.5 mm in skin. A time-gated excitation using 1,000 times higher F pulses can obtain the imaging depth of < 5 cm. To validate our estimates, in vivo whole-body imaging experiments are performed using small-animal models.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.