We developed the on-board BOCDA system for airplane and verified the flight environmental stability and durability through environmental test. The on-board BOCDA system adopted the polarization diversity technique and temporal gating technique to improve robustness of the BOCDA system. We successfully measured distribution of fiber Brillouin gain spectrum over 500m measurement range with 50mm spatial resolution, 60Hz sampling rate and ±13µ strain accuracy. Furthermore, we considered flight test to verify the validity of the BOCDA system. From these results, it was confirmed that BOCDA system has potential to be applied to an aircraft structure health monitoring system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.