Posttraumatic subacute ascending myelopathy is a rare late complication of spinal trauma. We present a case of 24-year-old male patient of motor vehicle accident who initially presented with T12 vertebral fracture and associated cord compression and signal changes in lower dorsal cord causing paraplegia with bladder and bowel involvement. In the subsequent week, he developed complete paraplegia with cord signal abnormality on magnetic resonance imaging extending cephalad from the injury site to involve the cervicomedullary junction. The patient clinically and radiologically improved over 6 weeks on steroid treatment.
Background:Patients undergoing elective orthopedic surgeries often incur excess blood loss necessitating transfusion. The preoperative placement of blood requests frequently overshoots the actual need resulting in unnecessary crossmatching.Aims:Our primary goal was to audit the blood utilization in elective orthopedic surgeries in our hospital over a 1-year period and recommend a blood ordering schedule.Materials and Methods:A retrospective analysis of patients who underwent elective orthopedic surgeries over a period of 1 year was done. The data collected include patients’ age, sex, type of surgical procedure, pre- and postoperative hemoglobin (Hb) levels, number of units crossmatched, returned, transfused, crossmatch to transfusion ratio (C:T), transfusion indices, estimated blood loss for each surgical procedure, and the actual and predicted fall in Hb. We propose a blood ordering schedule based on surgical blood ordering equation.Results and Conclusions:A total of 487 patients with a median age of 37±17 years (mean ± standard deviation) were evaluated. One thousand three hundred and seventy-seven units of blood were crossmatched and only 564 units were transfused to 260 patients. Fifty-nine percent of the units crossmatched were not transfused. Six of the 12 elective procedures had a C:T ratio higher than 2.5. Ten of the 12 procedures (83.3%) had a low transfusion index (TI < 0.5). The calculated red blood cell units were less than 0.5 in 5 of the 12 elective procedures, and hence we recommend a group and save policy for these procedures. Blood ordering schedule based on patient and surgical variables would provide an efficient way of blood utilization and management of resources.
Overview:Awake fiberoptic bronchoscope (FOB) guided intubation is the gold standard of airway management in patients with cervical spine injury. It is essential to sufficiently anesthetize the upper airway before the performance of awake FOB guided intubation in order to ensure patient comfort and cooperation. This randomized controlled study was performed to compare two methods of airway anesthesia, namely ultrasonic nebulization of local anesthetic and performance of airway blocks.Materials and Methods:A total of 50 adult patients with cervical spine injury were randomly allocated into two groups. Group L received airway anesthesia through ultrasonic nebulization of 10 ml of 4% lignocaine and Group NB received airway blocks (bilateral superior laryngeal and transtracheal recurrent laryngeal) each with 2 ml of 2% lignocaine and viscous lignocaine gargles. FOB guided orotracheal intubation was then performed. Hemodynamic variables at baseline and during the procedure, patient recall, vocal cord visibility, ease of intubation, coughing/gagging episodes, and signs of lignocaine toxicity were noted.Results:The observations did not reveal any significant differences in demographics or hemodynamic parameters at any time during the study. However, the time taken for intubation was significantly lower in Group NB as compared with the Group L. Group L had an increased number of coughing/gagging episodes as compared with Group NB. Vocal cord visibility and ease of intubation were better in patients who received airway blocks and hence the amount of supplemental lignocaine used was less in this group. Overall patient comfort was better in Group NB with fewer incidences of unpleasant recalls as compared with Group L.Conclusion:Upper airway blocks provide better quality of anesthesia than lignocaine nebulization as assessed by patient recall of procedure, coughing/gagging episodes, ease of intubation, vocal cord visibility, and time taken to intubate.
PurposeTo report complications in the management of complex closed proximal tibial fractures.MethodA retrospective study was conducted to analyze the infectious and noninfectious complications encountered in the management of high-energy Schatzker type V and VI tibial plateau fractures. All patients were treated at the level 1 trauma centre between January 2011 and March 2014. Sixty two patients were included in the study. The mean patient age was (43.16 ± 11.59) years with 60 males and 2 females. Infectious complications like superficial and deep infection, wound dehiscence, malalignment in the immediate postoperative period and in follow-up period were noted.ResultsThe overall complication rate was 30.65% (19 out of 62). Infectious complications were noted in 20.97% cases (13/62). In majority of the cases (8/13), superficial infection was seen which managed with regular dressing and antibiotic administration. The patients (5/13) who had developed deep-seated infection were subjected to repeated debridements, flap coverage, implant removal or amputation depending upon the host response. Thirteen patients had experienced noninfectious complications. Hardware related complications were noticed in six patients and four among them received a secondary procedure. Malalignment was observed in seven patients but only single patient underwent subsequent operative intervention.ConclusionProximal tibial plateau fractures especially Shatzker type V and VI are associated with extensive soft tissue damage even in closed injuries. The complications encountered in the management of these fractures can be minimized with appropriate patient selection and minimal soft tissue dissection.
BackgroundUnstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures.ObjectivesThis study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates.Patients and MethodsWe reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome.ResultsThere were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases.ConclusionsThe use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
Objective. To review functional outcome in high energy tibial plateau fractures treated by plating. Design. Retrospective analysis. Material and Methods. Sixty-five patients with Schatzker type V and type VI tibial plateau fractures treated with open reduction and internal fixation using plates were included in the study. The functional evaluation of the patients was carried out with Oxford knee scoring. Results. Fifty-four cases (83%) had Oxford knee score between 40 and 48. Seven (10.7%) had score between 30 and 39, three (4.6%) had score between 20 and 29, and one patient (1.5%) had a score of 18. Delayed union was seen in two cases and nonunion was seen in one case. The superficial wound infection was noticed in (9.2%) patients which was resolved with regular dressings and oral antibiotics. Three (4.6%) patients had developed deep wound infection and one among them had developed osteomyelitis. Conclusion. Open reduction and internal fixation in high energy tibial plateau fractures can provide good functional results in appropriately selected cases.
LipomaMagnetic resonance imaging a b s t r a c t Lipoma arborescens is villous proliferation of synovium and is often unilateral in the absence of any systemic disease. We report a case of 54 year old male presenting with bilateral lipoma arborescens associated with osteoarthritis. The diagnosis is often difficult due to similar symptomatology of lipoma arborescens and osteoarthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.