BackgroundInformation on the neonatal exposure to excipients is limited. Our aim was to describe the extent of excipient intake by Estonian neonates; to classify the excipients according to potential neonatal toxicity and thereby to measure the extent of exposure of neonates to potentially harmful excipients.MethodsA prospective cohort study that recorded all medicines prescribed to patients aged below 28 days admitted to Tartu University Hospital from 01.02-01.08 2008 and to Tallinn Children’s Hospital from 01.02- 01.08 2009 was conducted. Excipients were identified from Summaries of Product Characteristics and classified according to toxicity following a literature review.Results1961 prescriptions comprising 107 medicines were written for 348/490 neonates admitted. A total of 123 excipients were found in 1620 (83%) prescriptions and 93 (87%) medicines. 47 (38%) of these excipients were classified as potentially or known to be harmful to neonates. Most neonates (97%) received at least one medicine (median number 2) with potentially or known to be harmful excipient. Parabens were the most commonly used known to be harmful excipients and sodium metabisulphite the most commonly used potentially harmful excipient, received by 343 (99%) and 297 (85%) of treated neonates, respectively.ConclusionsHospitalised neonates in Estonia are commonly receiving a wide range of excipients with their medication. Quantitative information about excipients should be made available to pharmacists and neonatologists helping them to take into account excipient issues when selecting medicines and to monitor for adverse effects if administration of medicines containing excipients is unavoidable.
The potential of UV imaging as a new small scale flow-through dissolution testing platform and its ability to incorporate biorelevant media was tested. Furosemide was utilized as a model poorly soluble drug, and dissolution media simulating conditions in the small intestine (5/1.25 mM and 40/10 mM bile salt/phospholipid, pH 6.5) together with corresponding blank buffer were employed. Dissolution rates as a function of flow rate (0.2-1.0 mL/min) were determined directly from UV images, and by analysis of collected effluent using UV spectrophotometry. A good agreement in dissolution rates was observed, however repeatability of data based on measurement of collected effluent was superior to that obtained by UV imaging in the utilized prototypic flow cell. Both methods indicated that biorelevant media did not markedly increase the dissolution rate of furosemide as compared to buffer. Qualitatively, UV images indicated that uncontrolled swelling/precipitation of furosemide on the compact surface was occurring in some samples. In situ Raman spectroscopy together with X-ray diffraction analysis confirmed that the observations were not due to a solid form transformation of furosemide. The presented results highlight the complementary features of the utilized techniques and, in particular, the detailed information related to dissolution behavior which can be achieved by UV imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.