Vapour intrusion from the vadose zone-seven algorithms comparedProvoost, J.; Bosman, A.; Reijnders, L.; Bronders, J.; Touchant, K.; Swartjes, F. Published in:Journal of Soils and Sediments DOI:10.1007/s11368-009-0127-4 Link to publication Citation for published version (APA):Provoost, J., Bosman, A., Reijnders, L., Bronders, J., Touchant, K., & Swartjes, F. (2010). Vapour intrusion from the vadose zone-seven algorithms compared. Journal of Soils and Sediments, 10(3), 473-483. DOI: 10.1007/s11368-009-0127-4 General rightsIt is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulationsIf you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Abstract Background, aim and scope Vapours of volatile organic compounds (VOCs) emanating from contaminated soils may move through the unsaturated zone to the subsurface. VOC in the subsurface can be transported to the indoor air by convective air movement through openings in the foundation and basement. Once they have entered the building, they may cause adverse human health effects. Screening-level algorithms have been developed, which predict indoor air concentrations as a result of soil (vadose zone) contamination. The present study evaluates seven currently used screening-level algorithms, predicting vapour intrusion into buildings as a result of vadose zone contamination, regarding the accuracy of their predictions and their usefulness for screening purpose. Screening aims at identifying contaminated soils that should be further investigated as to the need of remediation and/or the presence of an intolerable human health risk. To be useful in this respect, screening-level algorithms should be sufficiently conservative so that they produce very few false-negative predictions but they should not be overly conservative because they might have insufficient discriminatory power. Materials and methods For this purpose, a comparison is made between observed and predicted soil air and indoor air concentrations from seven reasonably well-documented sites, where the vadose zone was contaminated with aromatic or chlorinated VOCs. The seven screening-level algorithms considered were: Vlier-Humaan (Be), Johnson and Ettinger model (USA), VolaSoil (NL), CSoil (NL), Risc (UK) and the dilution factor models from Norway and Sweden. Calculations are presented in two scatter plots (soil air and indoor air), each containing the predictions versus the observations. Differences between predicted and observed VOCs concentrations were evaluated on the basis of three statistical criteria to establish their accurateness and the usefulness for s...
Background, aim, and scope The membrane interphase probe (MIP™) from Geoprobe Systems® has frequently been applied in different countries for the characterization of soil contaminated with volatile organic carbons (VOCs). Experience shows that misinterpretation of the collected data is common. This is mainly due to the lack of understanding and knowledge related to the detectors used, their detection limits, and the sensitivity of the MIP system. It has been noticed that the sensitivity of the system given by the producer and by different users are rather optimistic, e.g., the values given are lower (= better) than those actually experienced in the field. A need for a better understanding of the MIP system sensitivity, combined with a more scientifically based interpretation of the collected data, exists. Materials and method Both laboratory tests (using solutions) as well as field measurements were carried out using different detector configurations to allow a better interpretation of the detector signals/system sensitivity and to collect qualitative information. These configurations were:(1) detectors stand alone; (2) the use of a 2-ml sample loop, and (3) a purge and trap system. The configurations (2) and (3) are used in combination with a capillary column to carry out on-site qualitative and semiquantitative analyses. Results and discussion With respect to the configuration of "detectors stand alone," detection limits for toluene (in aqueous solutions) range between 4 ppm (flame ionization detector-FID) and 10 ppm [photo ionization detector (PID)]. For chlorinated aliphatic hydrocarbons (CAHs), observed limits are 10 ppm (FID), 4-50 ppm (PID), and 3-10 ppm [dry electrolytic conductivity detector (DELCD)]. When using the 2-ml sample loop, relatively high concentrations have to be initially present in the soil. Observed detection limits for mono-aromatic hydrocarbons are 5-100 ppm; for CAHs, 1-50 ppm; for alkanes, 250-400 ppm; and for MTBE, 25 ppm. The application of purge and trap results in a better resolution and the detection of lower concentrations. Consequently, a better identification of the pollution with depth is possible. In this case, the detection limits are a function of the concentrations and the flushing time. In relation to the qualitative analyses, it was found that the configuration of the MIP-system with the built-in capillary column and the 2-ml sample loop or the purge and trap preconcentrator, respectively, are useful to carry out on-site analyses, thus allowing a better identification of the pollution in a vertical profile. Conclusions The measurements carried out using the MIP with detectors stand-alone or in combination with a loop or trap, or connected to a column, confirm that analysis is indeed very useful to characterize VOC source zones when knowing and understanding its performance. This relates mainly to the detection limits of the MIP system. For a selection of parameters, such limits have been obtained. These values seem to be more realistic than those found in the few referen...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.