The aim of this controlled, parallel design clinical study was to compare the effectiveness of an Er:YAG laser (ERL) to that of mechanical debridement using plastic curettes and antiseptic therapy for nonsurgical treatment of peri-implantitis. Twenty patients with moderate to advanced peri-implantitis lesions were randomly treated with either (1) an ERL using a cone-shaped glass fiber tip at an energy setting of 100 mJ/pulse and 10 pps (ERL), or (2) mechanical debridement using plastic curettes and antiseptic therapy with chlorhexidine digluconate (0.2%) (C). The following clinical parameters were measured at baseline, 3 and 6 months after treatment by one blinded and calibrated examiner: Plaque index (PI), bleeding on probing (BOP), probing depth (PD), gingival recession (GR) and clinical attachment level (CAL). At the baseline examination, there were no statistically significant differences in any of the investigated parameters. Mean value of BOP decreased in the ERL group from 83% at baseline to 31% after 6 months (P < 0.001) and in the C group from 80% at baseline to 58% after 6 months (P < 0.001). The difference between the two groups was statistically significant (P < 0.001, respectively). The sites treated with ERL demonstrated a mean CAL change from 5.8 +/- 1 mm at baseline to 5.1 +/- 1.1 mm (P < 0.01) after 6 months. The C sites demonstrated a mean CAL change from 6.2 +/- 1.5 mm at baseline to 5.6 +/- 1.6 mm (P < 0.001) after 6 months. After 6 months, the difference between the two groups was statistically not significant (P > 0.05). Within the limits of the present study, it was concluded that (i) at 6 months following treatment both therapies led to significant improvements of the investigated clinical parameters, and (ii) ERL resulted in a statistically significant higher reduction of BOP than C.
In the presence of a continuous cleft in the jaw and palate area, orthodontic forces (quadhelix) are apparently already sufficient to allow a skeletal expansion of the maxilla. Maxillary expansion using the quadhelix appliance represents a reasonable alternative to using conventional rapid maxillary expansion appliances among cleft patients.
The procedure outlined herein makes the reliable generation of patient-specific simulation models possible for facial soft tissue prediction in orthodontics.
The aim of this study was to evaluate fluorine-18 fluorodeoxyglucose ([(18)F]FDG) imaging of head and neck tumours using a second- or third-generation hybrid PET device. Results were compared with the findings of spiral computed tomography (CT) and magnetic resonance imaging (MRI), and, as regards lymph node metastasis, the ultrasound findings. A total of 116 patients with head and neck tumours (83 males and 33 females aged 27-88 years) were examined using a hybrid PET scanner after injection of 185-350 MBq of [(18)F]FDG (Picker Prism 2000 XP-PCD, Marconi Axis gamma-PET(2) AZ). Hybrid PET examinations were performed in list mode using an axial filter. Reconstruction of data was performed iteratively. Ninety-six patients underwent CT using a multislice technique (Siemens Somatom Plus 4, Marconi MX 8000), 18 patients underwent MRI and 100 patients were examined by ultrasound. All findings were verified by histology, which was considered the gold standard, or, in the event of negative histology, by follow-up. Correct diagnosis of the primary or recurrent lesion was made in 73 of 85 patients using the hybrid PET scanner, in 50 of 76 patients on CT and in 7 of 10 patients on MRI. Hybrid PET successfully visualised metastatic disease in cervical lymph nodes in 28 of 34 patients, while 23 of 31 were correctly diagnosed with CT, 3 of 4 with MRI and 30 of 33 with ultrasound. False positive results regarding lymph node metastasis were seen in three patients with hybrid PET, in 14 patients with CT and in 13 patients with ultrasound. MRI yielded no false positive results concerning lymph node metastasis. In one patient, unrecognised metastatic lesions were seen on hybrid PET elsewhere in the body (lung: n=1; bone: n=1). Additional malignant lesions at sites other than the head and neck tumour were found in three patients (one patient with lung cancer, one patient with pelvic metastasis due to a carcinoma of the prostate and one patient with pulmonary metastasis due to breast cancer). It is concluded that [(18)F]FDG PET with hybrid PET scanners is superior to CT and MRI in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement, whereas it is inferior to ultrasound in the detection of cervical lymph node metastasis.
Based on the documentation of the Munich Cancer Register our study is the first to present a detailed description of clinical and epidemiological data of patients suffering from head and neck malignomas.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.