A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary membrane Evalux 5A), and PA (Liposorber LA-40) were carried out 5 times each, with a 2-week interval, in 5 patients with heterozygous familial hypercholesterolemia. The same plasma separator (Plasmacure PS-60, polysulfone) was used in all cases, and the volume of plasma processed was set at 4 L. High removal rates were obtained of total cholesterol, LDL cholesterol, triglycerides TG, and apolipoprotein B (apoB) by all three methods, and no differences were observed. Lipoprotein (a), apoA-2, apoC-3, fibrinogen, and immunoglobulin M (IgM) showed significantly high removal rates by the DFPP and TFPP methods compared with the PA method. The sieving coefficient of albumin and high-density lipoprotein (HDL) cholesterol at 2 and 4 L of plasma processed exhibited high permeabilities using all three methods. Supplementing albumin was not necessary. An increase of the transmembrane pressure was observed in 1 case treated by DFPP but was not observed when using the TFPP or PA method. No changes were observed in serum interleukin 1beta (IL-1beta) or tumor necrosis factor-alpha (TNF-alpha) before and after treatment by any of the three methods. No remarkable side effects were observed using either the DFPP or TFPP method. The DFPP and TFPP methods showed efficacy and safety that was not inferior to the PA method in conventional LDL apheresis, and the dead-end method of the filter operation without the discarding of plasma was shown to be possible.
Bolted flange joint assembly has been widely used in chemical and nuclear plants. Insufficient bolt loads in the bolted flange joints lead to serious accidents. The insufficient bolt loads are due to inappropriate bolt tightening methods in many cases. In order to obtain target bolt loads by the torque control method, it is especially important to know a torque coefficient and an appropriate tightening sequence. Another problem exists because where mating flanges are tightened by multiple bolts. It is known that it is extremely difficult to obtain a uniform bolt loads among the multiple bolts. In this study, new and any experimentally examined, tightening sequences for the bolted flange joints using multiple bolts are proposed. As a result, the proposed tightening method was proved to be more effective than that by the ASME method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.