BACKGROUND AND PURPOSE:Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers.
Object
There is little evidence addressing whether procedures requiring adjunctive devices lead to an increased frequency of thromboembolic complications. The authors report their experience with 155 aneurysms treated with and without adjunctive devices.
Methods
The authors retrospectively reviewed their last 155 aneurysm coil placement procedures. The patients' records were reviewed for the following phenomena: 1) evidence of procedure-related thrombus formation; 2) clinical evidence of stroke; and 3) the presence of acute ischemia in the treated vascular territory on diffusion-weighted (DW) imaging.
Results
Of the 155 aneurysms treated in 132 patients, 66 were treated with coils only, 45 had stent-assisted coil placement, 33 underwent balloon remodeling, and in 11 stents were placed after balloon remodeling. Small DW imaging abnormalities were present in the treated vascular territory in 24% of cases (37 lesions). Specifically, 21 (32%) of 66 lesions in the coil-treated group, 6 (13%) of 45 in the stent-assisted coil treatment group, 8 (24%) of 33 in the balloon remodeling group, and 2 (18%) of 11 in the balloon and stent group showed DW imaging positivity. Furthermore, 25 (68%) of the 37 cases that were positive on DW imaging occurred in patients presenting with subarachnoid hemorrhage (SAH). Clinically evident stroke or transient ischemic attack was present in 10 (27%) of 37 cases, with 70% occurring in patients presenting with SAH.
Conclusions
Use of adjunctive devices in treating aneurysms does not appear to increase the frequency of embolic or ischemic events. The presence of DW imaging abnormalities and clinically evident stroke was actually less frequent when adjunctive devices were used and in electively treated cases. This was probably related to perioperative antiplatelet medical management.
BACKGROUND AND PURPOSE:Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT).
BACKGROUND AND PURPOSE:CBV is a key parameter in distinguishing penumbra from ischemic core. The purpose of this study was to compare CBV measurements acquired with standard PCT with ones obtained with C-arm CT in a canine stroke model.
BACKGROUND AND PURPOSE: Assessment of perfusion parameters is important in the selection of patients who are most likely to benefit from revascularization after an acute ischemic stroke. The aim of this study was to evaluate the feasibility of measuring cerebral perfusion parameters with the use of a novel high-speed C-arm CT acquisition in conjunction with a single intravenous injection of contrast.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.