Polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) have been monitored in air and deposition at four UK urban sites (London, Cardiff, Manchester and Stevenage) since the beginning of 1991; data from the first 2 years are presented here. Median Σ2,3,7,8-substituted PCDD/F concentrations in air were 3.2, 4.0, 3.5 and 2.6 pg/m(3) respectively for London, Cardiff, Manchester and Stevenage. Median Σ2,3,7,8-substituted PCDD/F deposition fluxes were 1.5 ng/m(2)/day in London, 1.4 ng/m(2)/day in Cardiff and Manchester and 0.79 ng/m(2)/day in Stevenage. Seasonal variations in the PCDD/F concentrations were observed at all sites for both air and deposition, with concentrations/fluxes generally elevated during the winter.
A gas chromatography–mass spectrometry (GC–MS) method was validated for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) from the FDA list of 93 harmful or potentially harmful constituents of mainstream cigarette smoke (MCS). Target analytes were extracted from total particulate matter using accelerated solvent extraction with a toluene/ethanol solvent mixture. Matrix artefacts were removed by two-step solid-phase extraction process. Three different GC–MS systems [GC–MS (single quadrupole), GC–MS/MS (triple quadrupole) and GC–HRMS (high resolution, magnetic sector)] using the same separation conditions were compared for the analysis of MCS of 3R4F Kentucky reference cigarettes generated under ISO and intense smoking regimes. The high mass resolution (m/∆m ≥ 10,000) and associated selectivity of detection by GC–HRMS provided the highest quality data for the target PAHs in MCS. Owing to the HR data acquisition mode enabling measurement of accurate mass, limits of quantification for PAHs were 5 to 15-fold lower for GC–HRMS than for GC–MS/MS and GC–MS. The presented study illustrates that the optimised sample preparation strategy followed by GC–HRMS analysis provides a fit-for-purpose and robust analytical approach allowing measurement of PAHs at (ultra)low concentrations in MCS. Furthermore, the study illustrates the importance and benefits of robust sample preparation and clean-up to compensate for limited selectivity when low-resolution MS is used.Electronic supplementary materialThe online version of this article (10.1186/s13065-018-0397-2) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.