In this study, both the intraobserver reproducibility and the interobserver reproducibility of DPI measurements were clinically acceptable.
Objective. To assess the potential of the power Doppler signal intensity rate of enhancement due to contrast agent wash-in for assessment of hepatic hemodynamics. Methods. With the use of standardized settings, power Doppler sonography was performed before and after administration of a contrast agent. Video-recorded examinations were digitized for offline analysis on a personal computer. The temporal changes of the power Doppler signal intensity were quantified to provide contrast agent wash-in curves. The contrast-enhanced Doppler perfusion index was defined by the ratio of the washin gradient of the hepatic artery and portal vein as contrast-enhanced Doppler perfusion index = hepatic artery gradient/(hepatic artery gradient + portal vein gradient). The contrast-enhanced Doppler perfusion index was evaluated at 4 contrast agent doses in each of 14 patients with liver metastases and 3 patients with hemangiomas. An in vitro flow model was used to determine the relationships between the power Doppler rate of enhancement and flow in vessels of 4, 8, and 12 mm in diameter. Results. In vivo, there was a significantly higher (P < .0001) mean contrast enhanced Doppler perfusion index in patients with liver metastases (mean, 0.59; 95% confidence interval, 0.54-0.63), compared with patients with hemangiomas (mean, 0.33; 95% confidence interval, 0.24-0.41). The corresponding coefficients of variations were 25% for patients with liver metastases and 31% for patients with hemangiomas. In vitro, the power Doppler rate of enhancement was proportional to flow speed and independent of vessel diameter. Conclusions. Measurement of the contrast-enhanced Doppler perfusion index may have potential in assessment of hepatic hemodynamics and focal liver disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.