Purpose: CT based dosimetry was performed one day after prostate cancer treatment by permanent seed implantation. Two techniques were used for implants. To investigate the impact of the two techniques in dose distribution we analyzed several dosimetric ct scans. Method and Materials: Patients with prostate cancer were treated with brachytherapy as monotherapy without neoadjunctive androgen deprivation between 01/00 and 12/04. Patient selection in both groups were staging of T1C, pretreatment PSA <8 and Gleason's score of < 6; the mean age in both groups was 65 years. Ultrasound volume study was performed two weeks prior to implant procedure. The dosimetry results from 40 patients divided into two groups were analyzed after full dose I‐125 implantation. Group one (20 patients) implanted using the Mick Applicator and group two (20 patients) were implanted using the Strand. CT transverse images of the implant volume were collected. Dose volume histogram parameters were analyzed for prostate volume changes, including D 90, V100, and V150. Results: The reference dosimetry was performed post‐implantation, one day after using computed tomography (CT). Variseed software was used for dosimetric evaluation of each implant to compare the D 90, V100, and V150 dose obtained by the two sets of study. The average prostate volume was 35cm cubed (range 25–59). In group one (using the Mick) the median D 90 was 98.4% (range) and was achieved in 9 out of 20 patients. A comprehensive evaluation is shown in table 1. In group two (using the strand) the median D 90 coverage was 108.5% (range) and was achieved in 14out of 20 patients. An elaborate evaluation is shown in Table 2. Conclusion: The above results clearly demonstrate that when we started using the strand we achieved a superior dosimetric outcome that is greater than the minimal therapeutic D 90 value of 140Gy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.