Collagen-based materials have become a staple in both research and the clinic. In wound care, collagen-based materials comprise a core gamut of biological dressings and therapeutic strategies. In research, collagen-based materials are employed in everything from 3D cultures to bioprinting. Soluble collagen is well characterized to undergo fibrillation at neutral pH and 37 °C. To remain stable, a neutralized collagen solution must be maintained at 4 °C. These physical characteristics of collagen impose limitations on its utility. In our previous work, we identified that the incorporation of a simple polyvinyl alcohol:borate hydrogel could improve the rate of collagen gel fibrillation. In this work we sought to further investigate the interactions of polyvinyl alcohol blend variants, as surfactant-like polymers, in comparison with known non-polymer surfactants. To conduct our investigations scaffold variants were created using increasing concentrations of polyvinyl alcohol, differing combinations of polymers, and non-polymer surfactants Tweens 20 and 80, and TritonX-100. Activation energy for collagen fibrillation was found to significantly decrease in the presence of polyvinyl alcohols (p < 0.01) at and above 0.4%w/v concentration. Further, addition of polyvinyl alcohol-graft-polyethylene glycol had the greatest enhancement (2.02 fold) on the fibrillation kinetics (p < 0.01), wetting properties and the stability of the collagen scaffolds post-freeze drying. Our results demonstrated that the addition of polyvinyl alcohol hydrogels to a collagen solution could stabilize collagen solution such that the solution could easily be lyophilized (at pH 7) and then reconstituted with water. Cells cultured in polyvinyl alcohol scaffolds also exhibited more organized F-actin, as well as a reduced abundance of pro-collagen and α-smooth actin. In conclusion, our results demonstrate for the first time that polyvinyl alcohol, preferably polyvinyl alcohol-graft-polyethylene glycol, directly affects the physical properties of collagen and the physiology of cells cultured within improving the utility of the combined material for both research and clinic needs.
Tendon reflexes were examined in 119 patients with idiopathic parkinsonism (IP) and 40 spouse controls to estimate the type and frequency of any alterations in the reflexes. Forty one of 119 patients and 2 of 40 controls had reflex ratings of 3+ at two or more sites (p < 0.001). There was no correlation of reflex score with the severity of disease or with the cardinal signs of IP. In 21 patients with asymmetric tendon jerks the side with the more active reflexes correlated with the side with greater parkinsonian signs. We conclude that an increase in tendon jerks is a feature of IP. The pathophysiology of this change in reflexes should be investigated further to establish if it is a heretofore overlooked manifestation of basal ganglia dysfunction or a link with other neurodegenerative diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.