There is an unacceptably high complication rate after reimplantation of the autologous bone following DC in pediatric TBI patients, especially in young children up to seven years of age. Artificial or synthetic cranioplasties may be considered as alternatives to initial bone flap reimplantation in the growing child. Despite the fact that DC is an effective treatment in TBI with persistent intracranial hypertension, it is important to realize that DC is not only combined with replacement of the autologous bone flap but also with a high rate of additional complications especially in pediatric patients.
There are no significant differences in long-term outcomes after open and retractor-endoscopic in situ decompression of the ulnar nerve in cubital tunnel syndrome. The short-term results are significantly better in endoscopic surgery.
The susceptibility-weighted 3-T MRI-based subthalamic nucleus localization shows the best accuracy compared with T2-weighted and fluid-attenuated inversion recovery 3-T MRI. Therefore, the susceptibility-weighted 3-T MRI should be preferred for surgical planning when the operation procedure is performed under general anesthesia without microelectrode recordings.
OBJECT The ActiGait drop foot stimulator is a promising technique for restoration of lost ankle function by an implantable hybrid stimulation system. It allows ankle dorsiflexion by active peroneal nerve stimulation during the swing phase of gait. In this paper the authors report the outcome of the first prospective study on a large number of patients with stroke-related drop foot. METHODS Twenty-seven patients who experienced a stroke and with persisting spastic leg paresis received an implantable ActiGait drop foot stimulator for restoration of ankle movement after successful surface test stimulation. After 3 to 5 weeks, the stimulator was activated, and gait speed, gait endurance, and activation time of the system were evaluated and compared with preoperative gait tests. In addition, patient satisfaction was assessed using a questionnaire. RESULTS Postoperative gait speed significantly improved from 33.9 seconds per 20 meters to 17.9 seconds per 20 meters (p < 0.0001), gait endurance from 196 meters in 6 minutes to 401 meters in 6 minutes (p < 0.0001), and activation time from 20.5 seconds to 10.6 seconds on average (p < 0.0001). In 2 patients with nerve injury, surgical repositioning of the electrode cuff became necessary. One patient showed a delayed wound healing, and in another patient the system had to be removed because of a wound infection. Marked improvement in mobility, social participation, and quality of life was confirmed by 89% to 96% of patients. CONCLUSIONS The ActiGait implantable drop foot stimulator improves gait speed, endurance, and quality of life in patients with stroke-related drop foot. Regarding gait speed, the ActiGait system appears to be advantageous compared with foot orthosis or surface stimulation devices. Randomized trials with more patients and longer observation periods are needed to prove the long-term benefit of this device.
OBJECTIVE Direct stimulation of the peroneal nerve by the ActiGait implantable drop foot stimulator is a potent therapy that was described previously for stroke-related drop foot. The authors report here successful long-term application of the ActiGait implantable drop foot stimulator in patients with multiple sclerosis (MS). METHODS Six patients with MS and 2 years of persisting central leg paresis received an implantable ActiGait drop foot stimulator after successful surface test stimulation. Ten weeks and 1 year after surgery, their gait speed, endurance, and safety were evaluated. Patient satisfaction was assessed with a questionnaire. RESULTS In the 20-m gait test, stimulation with the ActiGait stimulator significantly reduced the time needed, on average, by approximately 23.6% 10 weeks after surgery, and the time improved further by 36.3% after 1 year. The median distance covered by patients with the stimulator after 6 minutes of walking increased significantly from 217 m to 321 m and remained stable for 1 year; the distance covered by patients after surface stimulation was 264 m. Patients with an implanted ActiGait stimulator noticed pronounced improvement in their mobility, social participation, and quality of life. CONCLUSIONS The ActiGait implantable drop foot stimulator improved gait speed, endurance, and quality of life in all patients over a period of 1 year. It may serve as a new therapeutic option for patients with MS-related drop foot.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.