Conclusions:In conclusion, the inclusion of PLGF in the screening algorithm during first-trimester assessment, changed statistically significant the combined risk scores for Trisomy 21. Future studies should further investigate the impact of PLGF marker in screening algorithm for more convincing results. P01.04Cell-free DNA analysis in twin pregnancies after reduction because of fetal aneuploidy
to assess its performance using a clinical database of precisely phenotyped postmortem examinations. Methods: This DSS is knowledge-based and comprises a dedicated thesaurus of 294 syndromes and diseases. It operates by suggesting, at each step of the ultrasound examination, the best next symptom to check for in order to optimise the diagnostic pathway to the smallest number of possible diagnoses. This assistant was tested on a single-centre database of 209 cases of postmortem phenotypes with a definite diagnosis. The primary outcome was a target concordance rate > 90% between the postmortem diagnosis and the top-7 diagnoses given by SONIO when providing the full phenotype as input. Secondary outcomes included concordance for the top-5 and top-3 diagnoses; We also assessed a ''1-by-1'' model, providing only the anomalies sequentially prompted by the system, mimicking the use of the software in a real-life clinical setting. Results:The validation database covered 96 of the 294 (32.65%) syndromes and 79% of their overall prevalence in the SONIO thesaurus. SONIO failed to make the diagnosis on 7/209 cases. On average, each case displayed 6 anomalies, 3 of which were considered atypical for the condition. Using the 'full-phenotype' model, the success rate of the top-7 output of Sonio was 96.7% (202/209). This was 91.9% and 87.1% for the top-5 and top-3 outputs respectively. Using the ''1-by-1'' model, the correct diagnosis was within the top-7, top-5 and top-3 of SONIO's output in 79%, 73% and 68%. Conclusions: Sonio is a robust DSS with a success-rate > 95% for top-7 ranking diagnoses when the full phenotype is provided, using a large database of noisy real data. The success rate of 79% using the '1-by-1' model was understandably lower, given that SONIO's sequential queries may not systematically cover the full phenotype.VP17.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.