Measured local and spatially-averaged Nusselt numbers and friction factors (all timeaveraged) are presented which show the effects of temperature ratio and variable properties in a rectangular channel with rib turbulators, and an aspect ratio of 4. The ratio of air inlet stagnation temperature to local surface temperature T oi /T w varies from 0.66 to 0.95, and Reynolds numbers based on channel height range from 10,000 to 83,700. The square cross-section ribs are placed on two opposite surfaces, and are oriented at angles of ϩ45 deg and Ϫ45 deg, respectively, with respect to the bulk flow direction. The ratio of rib height to channel hydraulic diameter is 0.078, the rib pitch-to-height ratio is 10, and the ribs block 25 percent of the channel cross-sectional area. Ratios of globallyaveraged rib Nusselt numbers to baseline, constant property Nusselt numbers, Nu ញ /Nu o,cp , increase from 2.69 to 3.10 as the temperature ratio T oi /T w decreases from 0.95 to 0.66 (provided Reynolds number Re H
is approximately constant). Friction factor ratios f / f o,cp then decrease as T oi /T w decreases over this same range of values. In each case, a correlation equation is given which matches the measured global variations. Suchglobal changes are a result of local Nusselt number ratio increases with temperature ratio, which are especially pronounced on the flat surfaces just upstream and just downstream of individual ribs. Thermal performance parameters are also given, which are somewhat lower in the ribbed channel than in channels with dimples and/or protrusions mostly because of higher rib form drag and friction factors.
While Norovirus (NoV) is thought to replicate in B cells, in this PIDD cohort of CNI, B-cell lymphopenia was common, indicating that the presence of B lymphocytes is not essential for CNI.
SUMMARYGenetic algorithm (GA) and simulated annealing (SA) methods were employed to optimize the current distribution of a cooler made up of a large number of thermoelectric (TE) modules. The TE modules were grouped into several clusters in the flow direction, and the electric currents supplied to different clusters were adjusted separately to achieve maximum energy efficiency or minimum refrigeration temperature for different operating conditions and cooling requirements. Optimization results based on the design parameters of a large TE cooler showed considerable improvements in energy efficiency and refrigeration temperature when compared to the results of uniform current for the parallel-flow arrangement. On the other hand, results of the counter-flow arrangement showed only slight differences between uniform-and non-uniform-current optimizations. The optimization results of GA and SA were very close to each other. SA converged faster and was more computationally economical than GA for TE system optimization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.