Recent experiments have discovered giant and sensitive magneto-impedance and magneto-inductive effects in FeCoSiB amorphous wires. These effects include a sensitive change in an ac wire voltage with the application of a small dc longitudinal magnetic field. At low frequencies (1–10 kHz) the inductive voltage drops by 50% for a field of 2 Oe (25%/Oe) reflecting a strong field dependence of the circumferential permeability. At higher frequencies (0.1–10 MHz) when the skin effect is essential, the amplitude of the total wire voltage decreases by 40%–60% for fields of 3–10 Oe (about 10%/Oe). These effects exhibit no hysteresis for the variation of an applied field and can be obtained even in wires of 1 mm length and a few micrometer diameter. These characteristics are very useful to constitute a highly sensitive microsensor head to detect local fields of the order of 10−5 Oe. In this paper, we review recently obtained experimental results on magneto-inductive and magneto-impedance effects and present a detailed discussion for their mechanism, developing a general approach in terms of ac complex impedance in a magnetic conductor. In the case of a strong skin effect the total wire impedance depends on the circumferential permeability through the penetration depth, resulting in the giant magneto-impedance effect.
We analyzed and organized the reasons why the amorphous wire CMOS IC magneto-impedance sensor (MI sensor) has rapidly been mass-produced as the electronic compass chips for the smart phones, mobile phones, and the wrist watches. Comprehensive advantageous features regarding six terms of (1) microsizing and ultralow power consumption, (2) high linearity without any hysteresis for the magnetic field detection, (3) high sensitivity for magnetic field detection with a Pico-Tesla resolution, (4) quick response for detection of magnetic field, (5) high temperature stability, and (6) high reversibility against large disturbance magnetic field shock are based on the magneto-impedance effect in the amorphous wires. We have detected the biomagnetic field using the Pico-Tesla resolution MI sensor at the room temperature such as the magneto-cardiogram (MCG), the magneto-encephalogram (MEG), and the self-oscillatory magnetic field of guinea-pig stomach smooth muscles (in vitro) that suggest the origin of the biomagnetic field is probably pulsive flow of Ca2+through the muscle cell membrane.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.