An important amount of cytotoxic drug may accumulate in the workplace following the breakage of a vial containing an anticancer drug. Thanks to the monthly monitoring of the surface contamination in our compounding unit, a strong increase of cyclophosphamide contamination was highlighted in the storage area following the breakage of the vial, despite application of the emergency procedure. This study presents an analysis of chemical decontamination in the context of massive contamination. Samples were taken on the floor and on the caster of a storage shelf where the vial broke. The residual contamination was measured with a liquid chromatography-mass spectrometry/mass spectrometry method. An admixture of 10 À2 M sodium dodecyl sulfate and 70% isopropanol (SDS/IPA 8:2) was selected as the decontamination solution. High amounts of cyclophosphamide were retrieved. The initial contamination on the floor was over 20 ng/cm 2. Three decontaminations with SDS/IPA were carried out at Day 61, Day 68, and Day 71. The amount of cyclophosphamide decreased to 0.45 ng/cm 2 at D134. However, high values were still measured on the caster despite successive decontaminations, with a maximal value of 19.78 ng/cm 2 observed at Day 106. Continuous monitoring in our unit led us to highlight the inefficiency of our emergency procedure to eliminate high cyclophosphamide contamination. The procedure involving the SDS/IPA admixture was more efficient on the floor compared to the caster, which is a different surface type and porosity. This work highlights the importance of improving the procedures of incident management using contamination monitoring and repeated decontamination procedures adapted to different contaminants and surfaces.
Introduction Compounding robots are increasingly being implemented in hospital pharmacies. In our hospital, the recent acquisition of a robot (RIVATM, ARxIUM) for intravenous cancer drug compounding obliged us to replace the previously used infusion devices. The objective of the present study was to assess and qualify the new intravenous sets prior to their use in our hospital and prior to the implementation of the compounding robot. Materials and Methods The ChemoLockTM (ICU Medical) was compared with the devices used previously for compounding (BD PhaSealTM, Becton-Dickinson) and infusion (Connect-ZTM, Codan Medical). The connection/disconnection of infusion devices to/from 50 mL infusion bags was tested with a dynamometer (Multitest-i, Mecmesin). Leakage contamination was visualized by a methylene blue assay and was quantified in simulated pump infusions with 20 mg/mL quinine sulfate ( N = 36/group); after the analytical assay had been validated, quinine was detected by UV-spectrophotometry at 280 and 330 nm. Groups were compared using chi-squared or Mann–Whitney U tests. Results The connection/disconnection test showed that although all the devices complied with the current standard, there was a statistically significant difference in the mean ± standard deviation compression force (51.5 ± 11.6 for the Connect-ZTM vs. 60.3 ± 11.7 for the ChemoLockTM; p = 0.0005). Leaks were detected in 32 (29.1%) of the 110 tests of the ChemoLockTM. The contamination rates were also significantly different: 13.9% for the BD PhaSealTM versus 75.0% for the ChemoLockTM; p < 0.0001). Discussion/conclusion Our results showed that the new infusion device complied with current standards. However, the presence of contamination emphasizes the need for operators to use the recommended personal protective equipment. Further studies of contamination with cancer drugs are required.
Lactams. -Simple conditions are developed for the reaction of keto acids with dinucleophiles. The process is applied to parallel synthesis providing a 80-lactam library. -(MALAQUIN, S.; JIDA, M.; COURTIN, J.; LACONDE, G.; WILLAND, N.; DEPREZ*, B.; DEPREZ-POULAIN, R.; Tetrahedron Lett. 54 (2013) 6, 562-567, http://dx.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.