The rate of TLF was numerically higher in the BVS arm than in the CoCr-EES arm, although this difference was not statistically significant. VLST was observed only in the BVS arm at a rate of 1.6% between one and two years. Further studies are mandatory to investigate the risk of BVS relative to metallic stents for VLST, and the underlying mechanisms of BVS VLST.
Rationale and Objectives:We have developed a new contrast enhancement protocol for subtraction coronary computed tomography (SCCTA) requiring a short breath-holding time. In the protocol, test and main boluses were sequentially and automatically injected, and correct timings for pre-contrast and contrast-enhanced scans for main bolus were automatically determined only by the test bolus tracking. Combined with a fixed short main bolus injection for 7 seconds, the breath-holding time was shortened as possible. The purpose of this study was to evaluate whether use of this new protocol produced adequate quality images, taking into account calcified lesions and in-stent lumens.Materials and Methods: Patients (n = 127) with calcium scores of >400 Agatston units or a history of stent placement were enrolled. Breath-holding times were recorded, and image quality was visually evaluated by two observers.Results: The mean ± standard deviation breath-holding time was 13.2 ± 0.6 seconds. The mean ± SD computed tomography (CT) number of coronary arteries for the pre-contrast scan was sufficiently low [99.2 ± 32.2 Hounsfield units (HU)] and, simultaneously, that for SCCTA was 367.0 ± 77.2 HU. The rate of segments evaluated as unreadable was sufficiently low (3.8%).Conclusions: Use of the SCCTA protocol was efficient and allowed for a shorter breath-holding time and adequate diagnostic accuracy of SCCTA images, including images of calcified and stent implantation segments.
A 52-year-old woman presented with a one-week history of low-grade fever and dyspnea. A CT scan showed multiple pulmonary nodules with cavitation, as well as bilateral pleural thickenings with effusions. A specimen resected by video-assisted thoracoscopic surgery showed multiple confluent granulomas with central necrosis and granulomatous vasculitis. These findings were consistent with necrotizing sarcoid granulomatosis. An elevated serum soluble interleukin-2 receptor level became normal following clinical and radiological improvement. This indicates that the serum soluble interleukin-2 receptor can be a useful marker for the clinical management of necrotizing sarcoid granulomatosis.
The early phase arterial reaction after implantation of second-generation drug-eluting stents (2nd DES) and baremetal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remains unclear.The MECHANISM pilot study is a multi-center prospective registry that enrolled 24 STEMI patients (from 11 centers) who had undergone implantation of everolimus-eluting (n = 6), biolimus A9-eluting (n = 6) or zotarolimus-eluting stents (n = 6), or BMS (n = 6). Scheduled optical coherence tomography (OCT) was performed 2 weeks after implantation, and images were independently analyzed at a core laboratory in a blinded fashion. Intra-stent thrombus was quantitatively analyzed in terms of the maximal area and the percentage of cross-sections with thrombus (the numbers of cross-section with thrombus × 100 divided by total number of cross-sections within the stented segment). More than 90% of struts were already covered 2 weeks after the index procedure, regardless of the stent type. There were no differences in stent diameter, minimal lumen diameter, minimal lumen area, neointimal thickness, or the frequencies of malapposed and uncovered struts among the 4 groups. The quantity of intra-stent thrombus also did not differ among the 4 groups.The results of this pilot study suggest that the 2-week vascular responses seem to be similar among 2nd DES and BMS in STEMI patients. Considering the possible advantage of 2nd DES in the prevention of restenosis, 2nd DES are a feasible option for the treatment of patients with STEMI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.