Photodynamic therapy with stenting resulted in longer survival than stenting alone. Early PDT after diagnosis and multiple PDT treatments were shown to have survival benefits. Metal stent patency was longer in patients receiving PDT. Higher T-stage appears to be a predictor of early mortality in advanced bile duct cancer treated with PDT.
In evaluating patients complaining of shoulder pain, ultrasonography is an emerging imaging tool due to convenience, low cost, high sensitivity and specificity. However, normative values of ultrasound dimensions of the shoulder to be compared with pathologic findings in Korean adults are not provided yet. We evaluated the ultrasound dimensions of the rotator cuff, long head of biceps tendon, deltoid muscle and acromioclavicular joint in Korean healthy adults. Shoulder ultrasonography was performed on 200 shoulders from 100 healthy adults. The dimensions of the thickness of rotator cuff (supraspinatus, infraspinatus, subscapularis tendon), deltoid muscle, long head of biceps tendon, subacromial subdeltoid bursa, and acromioclavicular joint interval were measured in a standardized manner. Differences in measurements among sex, age, and dominant arms were compared.The thickness of rotator cuff tendons (supraspinatus, infraspinatus, subscapularis) and deltoid muscle were significantly different between men and women. The thickness of subacromial subdeltoid bursa was significantly different between men and women for non-dominant side. In rotator cuff tendon measurements, the differences between dominant and non-dominant shoulders were not significant, which means the asymptomatic contralateral shoulder can be used to estimate the normal reference values. When stratified by age divided by 10 years, the measurements of supraspinatus, subscapularis and deltoid thickness showed tendency of increase with the age. The acromioclavicular joint interval, on the other hand, revealed decreasing tendency. This report suggests normative values of ultrasound dimensions of healthy Korean population with varying age, and can be useful as reference values in evaluating shoulder pathology, especially in rotator cuff tendon pathology.
Objective To compare the accuracy of ultrasound (US)-guided and non-US-guided botulinum toxin (BTX) injection into the salivary glands (parotid and submandibular glands) of cadavers. Methods Two rehabilitation physician injected dye into three sites in the salivary glands (two sites in the parotid gland and one site in the submandibular gland) on one side of each cadaver (one was injected on the right side, while the other was injected on the left side), using either a non-US-guided injection procedure based on superficial landmarks or a US-guided procedure. Orange dye was used for the US-guided procedure, and green dye was used for the blind procedure. Two physicians uninvolved with the injection procedures and who were blinded to the method of injection dissected the cadavers to identify whether the dye was accurately injected into each target site. Results The accuracies of the blind and US-guided injections into the parotid gland were 79.17% and 95.83%, respectively. In the submandibular gland, the accuracies of the blind and US-guided injections were 50.00% and 91.67%, respectively. The difference in accuracy between the two procedures was statistically significant only in the submandibular gland (p=0.025). There were no significant differences in the accuracy of US-guided and non-US-guided injections between the two physicians for the two sites in the parotid gland (p=0.278 and p=0.146, respectively). Conclusion US-guided BTX injection into the submandibular gland offers significantly greater accuracy over blind injection. For the treatment of drooling by injecting BTX into the submandibular gland, clinicians should consider using US guidance for improved accuracy.
The clinical complications for microperforation patients were worse than those for macroperforation patients. However, the clinical prognoses of patients with perforations that occur during colonic ESD are favorable.
Cerebrotendinous xanthomatosis is a rare autosomal recessive disease that involves multiple organs, including the peripheral nervous system. The present study is the first to report the ultrasonographic findings of peripheral nerves in a patient with cerebrotendinous xanthomatosis. The patient presented with bilateral Achilles tendon enlargement and foot hypesthesia. Sonographic examination revealed hypoechoic, swollen peripheral nerves with enlarged bilateral Achilles tendons. Since the ultrasonographic findings revealed peripheral involvement, the diagnosis of cerebrotendinous xanthomatosis was established after laboratory and genetic studies along with clinical findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.