Although the mechanical properties of blood vessels have been studied extensively, the shear modulus of the blood vessel wall is still unknown. New data on the shear modulus of elasticity of rat arteries and its variation with axial stretch and blood pressure are presented. The data were obtained from a new instrument designed and constructed by us to perform simultaneous torsion, inflation, and longitudinal stretching tests. It was found under physiological conditions (pressure = 120 mmHg or 16 kPa; longitudinal stretch = 1.2 relative to zero-stress state), the shear modulus of normal rat thoracic aorta is G = 137 +/- 18 kPa. The difference of shear modulus at body temperature (37 degrees C) and room temperature (25 degrees C) is within 10%. The shear modulus varies significantly with changing longitudinal and circumferential strains in proportion to the strain energy due to these strains. A constitutive equation based on a pseudo strain energy function is proposed. The vessel wall is not transversely isotropic in the incremental sense. When the rat was subjected to high blood pressure due to constriction of its aorta, the shear modulus does not vary significantly with the length of time the animal was subjected to hypertension.
The aim of this study was the evaluation of the thrombogenicity and the biocompatibility of the SunMedical EVAHEART left ventricular assist system (LVAS) coated with 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer compared to a diamond-like carbon (DLC) coating. Four calves were implanted with the MPC polymer-coated LVAS. Eight calves were implanted with DLC coated LVAS. The thrombogenicity and biocompatibility of the pumps were evaluated. At explant, 60.0 +/- 37.2% (5-85%) of the pump surface area was still coated with MPC polymer after the duration of 45.0 +/- 32.0 days. In 1 out of 4 MPC and 2 out of 8 DLC coated pumps, there was a very small amount of thrombus around the seal ring; otherwise the blood contacting surfaces were free of thrombus. Major organs were normal except for a few lesions in kidneys from both groups. The MPC polymer coated EVAHEART LVAS seems to have low thrombogenicity and high biocompatibility similar to the DLC coated system. The current study demonstrated that the MPC polymer coating shows great promise for being used as an antithrombogenic substrate for the LVAS due to its ease of application, significant cost benefit, and reduction in anticoagulation therapy in acute postoperative period.
Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with the long-term observation of calves implanted with centrifugal blood pumps (EVAHEART, Sun Medical Technology Research Corporation, Nagano, Japan). Two healthy female Jersey calves were implanted with devices in the left thoracic cavity. A total of 22 treadmill exercise tests were performed after the 50th postoperative day. During exercise, the following parameters were compared with conditions at rest: heart rate, blood pressure, central venous oxygen saturation (SvO2), pump speed, and pump flow. The pump flow in a cardiac cycle was analyzed by separating the systole and diastole. Compared to the base data, statistically significant differences were found in the following interrelated parameters: the heart rate (66.8 +/- 5.2 vs. 106 +/- 9.7 bpm), mean pump flow (4.8 +/- 0.2 vs. 7.0 +/- 0.3 L/min), and volume of pump flow in diastole (26.0 +/- 1.8 vs. 13.5 +/- 2.5 ml). During exercise, the volume of pump flow in systole was 3 times larger than that measured in diastole. Blood pressure, SvO2, and pump speed did not change significantly from rest to exercise. These results suggested that the mean pump flow depends on the systolic pump flow. Therefore, the increase in the mean pump flow during exercise under constant pump speed was caused by an increase in the heart rate.
A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).
The purpose of this study was to evaluate the real time relationship between pump flow and pump differential pressure (D-P) during experimentally induced hypertension (HT). Two calves (80 and 68 kg) were implanted with the EVA-HEART centrifugal blood pump (SunMedical Technology Research Corp., Nagano, Japan) under general anesthesia. Blood pressure (BP) in diastole was increased to 100 mm Hg by norepinephrine to simulate HT. Pump flow, D-P, ECG, and BP were measured at pump speeds of 1,800, 2,100, and 2,300 rpm. All data were separated into systole and diastole, and pump flow during HT was compared with normotensive (NT) conditions at respective pump speeds. Diastolic BP was increased to 99.3+/-4.1 mm Hg from 66.5+/-4.4 mm Hg (p<0.01). D-P in systole was under 40 mm Hg (range of change was 10 to 40 mm Hg) even during HT. During NT, the average systolic pump flow volume was 60% of the total pump flow. However, during HT, the average systolic pump flow was 100% of total pump flow volume, although the pump flow volume in systole during HT decreased (33.1+/-5.7 vs. 25.9+/-4.0 ml/systole, p<0.01). In diastole, the average flow volume through the pump was 19.6+/-6.9 ml/diastole during NT and -2.2+/-11.1 ml/diastole during HT (p<0.01). The change in pump flow volume due to HT, in diastole, was greater than the change in pump flow in systole at each pump speed (p<0.001). This study suggests that the decrease of mean pump flow during HT is mainly due to the decrease of the diastolic pump flow and, to a much lesser degree, systolic pump flow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.