PURPOSE:
To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction.
METHODS:
Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables.
RESULTS:
This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 ± 60 µm (
P
< .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 µm. A significant difference in central vault values was observed between the < 0 and > 350 µm groups, the 0 to 200 and 201 to 350 µm groups, and the 0 to 200 and > 350 µm groups (
P
< .05). Eyes with a high vault value (> 750 µm in mydriasis) had lower CLR values (
P
< .001) and higher ACD values (
P
< .001) than eyes with a low vault value (< 100 µm in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (
P
< .001).
CONCLUSIONS:
CLR significantly affected anterior chamber depth and postoperative ICL vault.
[
J Refract Surg
. 2019;35(3):177–183.]
Background
The purpose of this study was to evaluate the ocular biometric parameters in adult cataract patients from China and create an anterior chamber depth (ACD) regression model.
Methods
The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract.
Results
The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.26 ± 1.70 D; corneal astigmatism (CA), 1.06 ± 0.96 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. ACD correlated positively with AL (Spearman coefficient, 0.544) and WTW (0.300), but negatively with LT (-0.660) and age (-0.285) (all P < 0.01). In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.641.
Conclusions
Cataract patients with longer AL and wider WTW have deeper ACD. With increasing age and lens thickening ACD becomes shallower. Based on the standardized coefficients of ACD multivariate regression analysis from the study, LT is the main factor that affects ACD, and is followed by AL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.