Abstract. The objective of this study is to demonstrate the feasibility of needle-based optical coherence tomography (OCT) and functional analysis of OCT data along the full pullback trajectory of the OCT measurement in the prostate, correlated with pathology. OCT images were recorded using a commercially available C7-XR™ OCT Intravascular Imaging System interfaced to a C7 Dragonfly™ intravascular 0.9-mm-diameter imaging probe. A computer program was constructed for automated image attenuation analysis. First, calibration of the OCT system for both the point spread function and the system roll-off was achieved by measurement of the OCT signal attenuation from an extremely weakly scattering medium (Intralipid® 0.0005 volume%). Second, the data were arranged in 31 radial wedges (pie slices) per circular segments consisting of 16 A-scans per wedge and 5 axial B-scans, resulting in an average A-scan per wedge. Third, the decay of the OCT signal is analyzed over 50 pixels (500 μm) in depth, starting from the first found maximum data point. Fourth, for visualization, the data were grouped with a corresponding color representing a specific μ oct range according to their attenuation coefficient. Finally, the analyses were compared to histopathology. To ensure that each single use sterile imaging probe is comparable to the measurements of the other imaging probes, the probe-to-probe variations were analyzed by measuring attenuation coefficients of 0.03, 6.5, 11.4, 17, and 22.7 volume% Intralipid®. Experiments were repeated five times per probe for four probes. Inter-and intraprobe variation in the measured attenuation of Intralipid samples with scattering properties similar to that of the prostate was <8% of the mean values. Mean attenuation coefficients in the prostate were 3.8 mmfor parts of the tissue that were classified as benign (SD: 0.8 mm −1 , minimum: 2.2 mm −1 , maximum: 8.9 mm −1 ) and 4.1 mm −1 for parts of tissue that were classified as malignant (SD: 1.2 mm −1 , minimum: 2.5 mm −1 , maximum: 9.0 mm −1 ). In benign areas, the tissue looked homogeneous, whereas in malignant areas, small glandular structures were seen. However, not all areas in which a high attenuation coefficient became apparent corresponded to areas of prostate cancer. This paper describes the first in-tissue needle-based OCT imaging and three-dimensional optical attenuation analysis of prostate tissue that indicates a correlation with pathology. Fully automated attenuation coefficient analysis was performed at 1300 nm over the full pullback. Correlation with pathology was achieved by coregistration of three-dimensional (3-D) OCT attenuation maps with 3-D pathology of the prostate. This may contribute to the current challenge of prostate imaging and the rising interest in focal therapy for reduction of side effects occurring with current therapies.
Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.
Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is available. The aim of the current study was to compare the clinical outcome after MitraClip treatment in patients with versus without atrial fibrillation. Between January 2009 and January 2016, all consecutive patients treated with a MitraClip in 5 Dutch centers were included. Outcome measures were survival, symptoms, MR grade, and stroke incidence. In total, 618 patients were treated with a MitraClip. Patients with AF were older, had higher N-terminal B-type natriuretic peptide levels, more tricuspid regurgitation, less often coronary artery disease and a better left ventricular function. Survival of patients treated with the MitraClip was similar for patients with AF (82%) and without AF (non-AF; 85%) after 1 year (p = 0.30), but significantly different after 5-year follow-up (AF 34%; non-AF 47%; p = 0.006). After 1 month, 64% of the patients with AF were in New York Heart Association class I or II, in contrast to 77% of the patients without AF (p = 0.001). The stroke incidence appeared not to be significantly different (AF 1.8%; non-AF 1.0%; p = 0.40). In conclusion, patients with AF had similar 1-year survival, MR reduction, and stroke incidence compared with non-AF patients. However, MitraClip patients with AF had reduced long-term survival and remained more symptomatic compared with those without AF.
The aim of the current study was to investigate whether stress echocardiography improves selection of patients who might have clinical benefit from percutaneous mitral valve repair with the MitraClip. In total, 39 patients selected for MitraClip implantation underwent preprocedural low-dose stress (dobutamine or handgrip) echocardiography from which stroke volume, ejection fraction and MR grade were measured. Outcome after MitraClip implantation was determined by New York Heart Association classification and Quality of Life questionnaires. Clinical benefit from MitraClip treatment was defined as survival and NYHA class I–II at 6 months follow-up. In total, 36 patients with a technically successful procedure were included in the analysis (mean age 79 ± 8 years, 47% male, 50% functional MR). Clinical benefit was achieved in 18 patients. All seven patients with MR decreasing during stress remained in NYHA III–IV or died within 6 months, while 62% (18 out of 29) of the patients with stable or increased MR during stress had clinical benefit (p = 0.008). Significant increase in Quality of Life on 4/8 subscales of the RAND Short Form-36 questionnaire was observed: Physical Functioning (p < 0.001), Social Functioning (p < 0.001), Mental Health (p = 0.022) and Vitality (p = 0.026) was seen in patients with an increase in stroke volume during stress echocardiography. Patients with a decreased MR during preprocedural stress echocardiography remained more symptomatic than patients with a stable or increased MR during stress. Stress echocardiography may support patient selection for percutaneous mitral valve repair. Electronic supplementary material The online version of this article (10.1007/s10554-018-1507-x) contains supplementary material, which is available to authorized users.
This matched analysis suggests a lower mortality hazard for MitraClip intervention in a high-risk population with symptomatic mitral regurgitation when compared with conservative management alone.
Guidelines suggest using frailty characteristics in the work-up for a transcatheter aortic valve implantation (TAVI). There are many frailty-screening tools with different components. The prognostic value of the individual parameters in frailty is as yet unclear. The objective of this systematic review and meta-analysis was to find and pool predictors for 1-year mortality after TAVI. We followed a twostep approach. First, we searched for randomised controlled trials on TAVI to identify frailty parameters used in these studies. Second, we searched for publications on these frailty parameters. Articles were included for pooled analysis if the studied frailty parameters were dichotomised with clear cutoff values based on common standards or clinical practice and reported adjusted hazard ratios (HR) of 1-year mortality after TAVI. We calculated pooled effect estimates of 49 studies based on dichotomised frailty scores (
Aims: Treatment strategies of high-risk patients with mitral regurgitation (MR) differ between disease based on functional and disease based on degenerative origin. In the present study, we aimed to evaluate the effect of surgical, percutaneous, or conservative treatment of MR according to MV mechanism, for high-risk patients.Methods and results: Survival outcomes of MitraClip, surgical, or conservative strategies were compared for 688 high-risk patients with functional MR and 275 with degenerative MR. Cox regression and propensity analyses were used to correct for differences in baseline characteristics. For functional MR, conservative treatment proved to have a higher mortality hazard when compared to MitraClip treatment (hazard ratio [HR] 1.79, 95% confidence interval [CI]: 1.34 to 2.39, p<0.001), while there was no significant difference in mortality hazard between MitraClip and surgery (HR 0.86, 95% CI: 0.54 to 1.38, p=0.541). For degenerative MR, no clear significant benefit was found when comparing MitraClip to conservative and surgical treatment.Conclusions: High-risk patients with symptomatic functional MR have reduced mortality when undergoing MitraClip intervention, compared to those receiving conservative treatment.
Background: High-risk patients with mitral regurgitation (
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.