Rapid DNA identification is the use of a rugged, field-deployable system to generate short tandem repeat (STR) profiles in law enforcement, military, immigration, and homeland security applications. A performance verification study was conducted on the ANDE Rapid DNA identification system using FlexPlex27, a highly multiplexed, 27 locus assay that generates data for the expanded CODIS core loci and all additional STR loci required for international databasing. The assay contains 23 autosomal loci (D1S1656, D2S1338, D2S441, D3S1358, D5S81, D6S1043, D7S820, D8S1179, D10S1248, D12S391, D13S317, D16S539, D18S51, D19S433, D21S11, D22S1045, FGA, CSF1PO, Penta E, TH01, vWA, TPOX, and SE33), three Y-chromosomal loci (DYS391, DYS576, and DYS570), and Amelogenin. Study results demonstrate that the instrument is reliable, reproducible, accurate, robust, and ready for a large scale, comprehensive developmental validation by NDIS-participating laboratories. The additional loci in the FlexPlex assay allow for improved STR profile sharing globally, increase the power of discrimination for identification matches, and improve the effectiveness of kinship analyses.Electronic supplementary materialThe online version of this article (doi:10.1007/s00414-017-1567-9) contains supplementary material, which is available to authorized users.
A developmental validation was performed to demonstrate reliability, reproducibility and robustness of the ANDE System with the FlexPlex assay, including an integrated Expert System, across a number of laboratories and buccal sample variations. Previously, the related DNAscan™/ANDE 4C Rapid DNA System using the PowerPlex ® 16 assay and integrated Expert System Software received NDIS approval in March 2016. The enhanced ANDE instrument, referred to as ANDE 6C, and the accompanying 6-dye, 27-locus STR assay, referred to as FlexPlex, have been developed to be compatible with all widely used global loci, including the expanded set of the CODIS core 20 loci.Six forensic and research laboratories participated in the FlexPlex Rapid DNA developmental validation experiments, testing a total of 2045 swabs, including those obtained from 1387 unique individuals. The goal of this extensive and comprehensive validation was to thoroughly evaluate and document the ANDE System and its internal Expert System to reliably genotype reference buccal swab samples in a manner compliant with the FBI's Quality Assurance Standards and the NDIS Operational Procedures.The ANDE System, including automated Expert System analysis, generated reproducible and concordant results for buccal swabs when testing various instruments at different laboratories by a number of different operators. When testing a number of non-human DNAs, including oral bacteria, the ANDE System and FlexPlex assay demonstrated limited cross-reactivity. Potential PCR inhibitors were evaluated as part of the validation and no inhibition was detected. Reproducible and concordant profiles were generated from buccal swab samples collected with a limit of detection appropriate for buccal swab collections from arrestees. The precision and resolution of the System met industry standards for detection of microvariants and single base resolution.The integrated Expert System appropriately demonstrated the ability to correctly pass or fail profiles for CODIS upload without human review. During this comprehensive developmental validation, the ANDE System successfully interpreted over 2000 samples tested with over 99.99% concordant alleles. The data package described herein led to the ANDE System with the FlexPlex assay receiving NDIS approval in June 2018.
Since the implementation of forensic DNA typing in labs more than 20 years ago, the analysis procedures and data interpretation have always been conducted in a laboratory by highly trained and qualified scientific personnel. Rapid DNA technology has the potential to expand testing capabilities within forensic laboratories and to allow forensic STR analysis to be performed outside the physical boundaries of the traditional laboratory. The developmental validation of the DNAscan/ANDE Rapid DNA Analysis System was completed using a BioChipSet™ Cassette consumable designed for high DNA content samples, such as single source buccal swabs. A total of eight laboratories participated in the testing which totaled over 2300 swabs, and included nearly 1400 unique individuals. The goal of this extensive study was to obtain, document, analyze, and assess DNAscan and its internal Expert System to reliably genotype reference samples in a manner compliant with the FBI's Quality Assurance Standards (QAS) and the NDIS Operational Procedures. The DNAscan System provided high quality, concordant results for reference buccal swabs, including automated data analysis with an integrated Expert System. Seven external laboratories and NetBio, the developer of the technology, participated in the validation testing demonstrating the reproducibility and reliability of the system and its successful use in a variety of settings by numerous operators. The DNAscan System demonstrated limited cross reactivity with other species, was resilient in the presence of numerous inhibitors, and provided reproducible results for both buccal and purified DNA samples with sensitivity at a level appropriate for buccal swabs. The precision and resolution of the system met industry standards for detection of micro-variants and displayed single base resolution. PCR-based studies provided confidence that the system was robust and that the amplification reaction had been optimized to provide high quality results. The DNAscan integrated Expert System was examined as part of the Developmental Validation and successfully interpreted the over 2000 samples tested with over 99.998% concordant alleles. The system appropriately flagged samples for human review and failed both mixed samples and samples with insufficient genetic information. These results demonstrated the integrated Expert System makes correct allele calls without human intervention.
Three commercially available integrated rapid DNA instruments were tested as a part of a rapid DNA maturity assessment in July of 2018. The assessment was conducted with sets of blinded single-source reference samples provided to participants for testing on the individual rapid platforms within their laboratories. The data were returned to the National Institute of Standards and Technology (NIST) for review and analysis. Both FBI-defined automated review (Rapid DNA Analysis) and manual review (Modified Rapid DNA Analysis) of the datasets were conducted to assess the success of genotyping the 20 Combined DNA Index System (CODIS) core STR loci and full profiles generated by the instruments. Genotype results from the multiple platforms, participating laboratories, and STR typing chemistries were combined into a single analysis. The Rapid DNA Analysis resulted in a success rate of 80% for full profiles (85% for the 20 CODIS core loci) with automated analysis. Modified Rapid DNA Analysis resulted in a success rate of 90% for both the CODIS 20 core loci and full profiles (all attempted loci per chemistry). An analysis of the peak height ratios demonstrated that 95% of all heterozygous alleles were above 59% heterozygote balance. For base-pair sizing precision, the precision was below the standard 0.5 bp deviation for both the ANDE 6C System and the RapidHIT 200.
As short tandem repeat markers remain the foundation of human identification throughout the world, new STR multiplexes require rigorous testing to ensure the assays are sufficiently robust and reliable for genotyping purposes. The PowerPlex(®) 18D System was created for the direct amplification of buccal and blood samples from FTA(®) storage cards and reliably accommodates other sample materials. The PowerPlex(®) 18D System allows simultaneous amplification of the 13 CODIS loci and amelogenin along with four additional loci: Penta E, Penta D, D2S1338, and D19S433. To demonstrate suitability for human identification testing, the PowerPlex(®) 18D System was tested for sensitivity, concordance, inhibitor tolerance, and performance with thermal cycling and reaction condition variation following SWGDAM developmental validation guidelines. Given these results, PowerPlex(®) 18D System can confidently be used for forensic and human identification testing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.