BackgroundKidney allografts with multiple renal arteries (MRA) are not infrequent and have been historically associated with a higher risk of developing vascular and urologic complications. Reports of kidney transplantation using MRA allografts in the pediatric population remain scarce. The aim of this study was to evaluate if transplantation of allografts with MRA with a surgical intent of creating a single arterial inflow using vascular reconstruction techniques when required, and without the routine use of surgical drains or ureteral stents, is associated with an increased risk of complications when compared to single renal artery (SRA) grafts.MethodsWe retrospectively analyzed all pediatric renal transplant recipients performed by a single surgeon at our center between January 2015 and June 2022. Donor and recipient demographics, intraoperative data, and recipient outcomes were included. Recipients were divided into two groups based on SRA vs. MRA. Baseline variables were described using frequency distributions for categorical variables and means and standard errors for continuous variables. Comparisons of those distributions between the two groups were performed using standard chi-squared and t-tests. Time-to-event distributions were compared using the log-rank test.ResultsForty-nine pediatric transplant recipients were analyzed. Of these, 9 had donors with MRA (Group 1) and 40 had donors with SRA (Group 2). Native kidney and liver mobilization was performed in 44.4% (4/9) of Group 1 vs. 60.0% (24/40) of Group 2 cases (p = 0.39). There were no cases of delayed graft function or graft primary nonfunction. No surgical drainage or ureteral stents were used in any of the cases. One patient in Group 2 developed a distal ureter stricture. The geometric mean serum creatinine at 6- and 12-months posttransplant was 0.7 */ 1.2 and 0.9 */ 1.2 mg/dl in Group 1 and 0.7 */ 1.1 and 0.7 */ 1.1 mg/dl in Group 2. Two death-censored graft failures were observed in Group 2, with no significant difference observed between the two groups (p = 0.48).ConclusionsOur study demonstrates that pediatric renal transplantation with MRA grafts, using a surgical approach to achieve a single renal artery ostium, can be safely performed while achieving similar outcomes as SRA grafts and with a low complication rate.
Background: Multiple renal arteries (MRA) are often encountered during living-donor kidney transplantation (LDKT), requiring surgeons to pursue complex renovascular reconstructions prior to graft implantation. With improvements in reconstruction and anastomosis techniques, allografts with MRA can be successfully transplanted with similar outcomes to allografts with a single renal artery. Here, we describe in detail various surgical techniques for reconstruction of MRA grafts with the intent of creating a single arterial inflow.Methods: We retrospectively reviewed the medical records of all LDKT recipients with laparoscopically procured MRA kidneys between March 2008 and July 2021. Recipient and donor characteristics, operative data, type of reconstruction, and recipient outcomes were analyzed. The primary outcomes were the incidence of developing delayed graft function (DGF) and/or a vascular or urological complication within 12 months post-transplant.Results: Seventy-three LDKT recipients of MRA donor allografts were evaluated. Two renal arteries (RA) were encountered in 62 allografts (84.9%) and three RA in 11 allografts (15.1%). Renal artery reconstruction was performed in 95.8% (70/73) of patients. Eighteen different reconstruction techniques of MRA were utilized, the most common being side-to-side anastomosis in allografts with two RA (N = 44) and side-to-side-to-side anastomosis in allografts with three RA (N = 4). Interposition grafting was performed in seven cases (9.6%). A single ostium was created in 69 cases (94.5%), and the median warm ischemia time was 27 (range 20–42) minutes. None of the patients developed DGF or post-operative vascular or urological complications. Median creatinine at 3, 6, and 12 months post-transplant remained stable at 1.1 mg/dl. With a median follow-up of 30.4 months post-transplant, only one graft failure has been observed–death-censored graft survival was 98.6%.Conclusion: Complex reconstruction techniques to create a single renal artery ostium for graft implantation anastomosis in allografts with MRA show acceptable warm ischemic times, with no increased risk of post-operative vascular or urological complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.