The objective of the present study was to evaluate whether integrated 18 F-FDG PET/MR imaging could improve the diagnostic workup in patients with cardiac masses. Methods: Twenty patients were prospectively assessed using integrated cardiac 18 F-FDG PET/MR imaging: 16 patients with cardiac masses of unknown identity and 4 patients with cardiac sarcoma after surgical therapy. All scans were obtained on an integrated 3-T PET/MR device. The MR protocol consisted of half Fourier acquisition single-shot turbo spin-echo sequence, cine, and T2-weighted images as well as T1-weighted images before and after injection of gadobutrol. PET data were acquired simultaneously with the MR scan after injection of 199 ± 58 MBq of 18 F-FDG. Patients were prepared with a high-fat, lowcarbohydrate diet in a period of 24 h before the examination, and 50 IU/kg of unfractionated heparin were administered intravenously 15 min before 18 F-FDG injection. Results: Cardiac masses were diagnosed as follows: metastases, 3; direct tumor infiltration via pulmonary vein, 1; local relapse of primary sarcoma after surgery, 2; Burkitt lymphoma, 1; scar/patch tissue after surgery of primary sarcoma, 2; myxoma, 4; fibroelastoma, 1; caseous calcification of mitral annulus, 3; and thrombus, 3. The maximum standardized uptake value (SUV max ) in malignant lesions was significantly higher than in nonmalignant cases (13.2 ± 6.2 vs. 2.3 ± 1.2, P 5 0.0004). When a threshold of 5.2 or greater was used, SUV max was found to yield 100% sensitivity and 92% specificity for the differentiation between malignant and nonmalignant cases. T2-weighted hyperintensity and contrast enhancement both yielded 100% sensitivity but a weak specificity of 54% and 46%, respectively. Morphologic tumor features as assessed by cine MR imaging yielded 86% sensitivity and 92% specificity. Consent interpretation using all available MR features yielded 100% sensitivity and 92% specificity. A Boolean 'AND' combination of an SUV max of 5.2 or greater with consent MR image interpretation improved sensitivity and specificity to 100%. Conclusion: In selected patients, 18 F-FDG PET/MR imaging can improve the noninvasive diagnosis and follow-up of cardiac masses.
We designed, constructed, and evaluated a new device to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. We designed this system for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicone rubber neck chamber, a stepping motor-driven electro-deposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.
Selective internal radiation therapy (SIRT) using 90-yttrium is a local therapy for unresectable liver malignancies. Non-targeted 90-yttrium diversion via a patent hepatic falciform artery (HFA) is seen as risk for periprocedural complications. Therefore, this study aimed to evaluate the impact of a patent HFA on SIRT. 606 patients with SIRT between 2006 and 2012 were evaluated retrospectively. SIRT preparation was performed by digital subtraction angiography including 99mTc-HSAM administration and subsequent SPECT/CT. Patients with an angiographically patent HFA were analyzed for procedural consequences and complications. 19 of 606 patients (3%) with an angiographically patent HFA were identified. Only 11 of these 19 patients received 90-yttrium in the hepatic vessel bed containing the HFA. Initial coil embolization of the HFA succeeded only in three of 11 patients. Out of the eight remaining patients four had no abdominal wall 99mTc-HSAM accumulation. The other four patients presented with an abdominal wall 99mTc-HSAM accumulation, for those a reattempt of HFA embolization was performed or ice packs were administered on the abdominal wall during SIRT. In summary, all patients tolerated SIRT well. A patent HFA should not be considered a SIRT contraindication. In patients with abdominal wall 99mTc-HSAM accumulation HFA embolization or ice pack administration seems to prevent complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.