Serial imaging is frequently performed on patients with diseases of the brain, to track and observe changes. Magnetic resonance imaging provides very detailed and rich information, and is therefore used frequently for this application. The data provided by MR can be so plentiful; however, that it obfuscates the information the radiologist seeks. A system which could reduce the large quantity of primitive data to a smaller and more informative subset of data, emphasizing change, would be useful. This article discusses motivating factors for the production of an automated process to this effect, and reviews the approaches of previous authors. The discussion is focused on brain tumors and multiple sclerosis, but many of the ideas are applicable to other disease processes, as well.
The goal of this study was to create an algorithm which would quantitatively compare serial magnetic resonance imaging studies of brain-tumor patients. A novel algorithm and a standard classify-subtract algorithm were constructed. The ability of both algorithms to detect and characterize changes was compared using a series of digital phantoms. The novel algorithm achieved a mean sensitivity of 0.87 (compared with 0.59 for classify-subtract) and a mean specificity of 0.98 (compared with 0.92 for classify-subtract) with regard to identification of voxels as changing or unchanging and classification of voxels into types of change. The novel algorithm achieved perfect specificity in seven of the nine experiments. The novel algorithm was additionally applied to a short series of clinical cases, where it was shown to identify visually subtle changes. Automated change detection and characterization could facilitate objective review and understanding of serial magnetic resonance imaging studies in brain-tumor patients.
An algorithm was developed which compares serial MRI brain examinations of brain tumor patients and judges them as either Bstable^or Bprogressing^. A set of 88 serial MR cases were obtained, consisting of cases which were stable and remained stable for at least 8 months, cases which were stable but progressed in less than 8 months, and cases which were progressing. The algorithm was run and its output was compared to the original clinical interpretation. Of the exam pairs which were judged stable and which remained stable at least 8 months after the later examination, the algorithm diagnosed 45/46 as stable. For exam pairs judged to be progressing, the algorithm judged 15/17 to be progressing. Of the exam pairs which were judged stable, but which went on to progress less than 8 months after the later of the pair, 16/25 were judged by the algorithm to be progressing.
In this study, we present preliminary data on the effect of automated 3D image alignment on the time to arrive at a decision about an imaging finding, the agreement of multiple of multiple observers, the prevalence of comparison examinations, and technical success rates for the image alignment algorithm. We found that automated image alignment reduced the average time to make a decision by 25% for cases where the structures are rigid, and when the scanning protocol is similar. For cases where these are not true, there is little or no benefit. In our practice, 54% of cases had prior examinations that could be automatically aligned. The overall benefit seen in our department for highly similar exams might be 20% for neuro and 10% for body; the benefit seen in other practices is likely to vary based on scanning practices and prevalence of prior examinations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.