A distributed health data network is a system that allows secure remote analysis of separate data sets, each comprising a different medical organization's or health plan's records. Distributed health data networks are currently being planned that could cover millions of people, permitting studies of comparative clinical effectiveness, best practices, diffusion of medical technologies, and quality of care. These networks could also support assessment of medical product safety and other public health needs. Distributed network technologies allow data holders to control all uses of their data, which overcomes many practical obstacles related to confidentiality, regulation, and proprietary interests. Some of the challenges and potential methods of operation of a multipurpose, multi-institutional distributed health data network are described.
To estimate real-world off-label use of sodium-glucose cotransporter 2 (SGLT2) inhibitors in patients with type 1 diabetes, estimate rates of diabetic ketoacidosis (DKA), and compare them with DKA rates observed in sotagliflozin clinical trials. RESEARCH DESIGN AND METHODSWe identified initiators of SGLT2 inhibitors in the Sentinel System from March 2013 to June 2018, determined the prevalence of type 1 diabetes using a narrow and a broad definition, and measured rates of DKA using administrative claims data. Standardized incidence ratios (SIRs) were calculated using age-and sexspecific follow-up time in Sentinel and age-and sex-specific DKA rates from sotagliflozin trials 309, 310, and 312. RESULTSAmong 475,527 initiators of SGLT2 inhibitors, 0.50% and 0.92% met narrow and broad criteria for type 1 diabetes, respectively. Rates of DKA in the narrow and broad groups were 7.1/100 person-years and 4.3/100 person-years, respectively. Among patients who met narrow criteria for type 1 diabetes, rates of DKA were highest for patients aged 25-44 years, especially females aged 25-44 years (19.7/100 person-years). More DKA events were observed during off-label use of SGLT2 inhibitors in Sentinel than would be expected based on sotagliflozin clinical trials (SIR 5 1.83; 95% CI 1.45-2.28). CONCLUSIONSReal-world off-label use of SGLT2 inhibitors among patients with type 1 diabetes accounted for a small proportion of overall SGLT2 inhibitor use. However, the risk for DKA during off-label use was notable, especially among young, female patients. Although real-word rates of DKA exceeded the expectation based on clinical trials, results should be interpreted with caution due to differences in study methods, patient samples, and study drugs.Inhibition of sodium-glucose cotransporter 2 (SGLT2) in the proximal tubules suppresses renal glucose reabsorption, resulting in urinary glucose excretion and lowering of blood glucose in patients with diabetes. Canagliflozin (1), dapagliflozin (2), empagliflozin (3), and ertugliflozin (4) are SGLT2 inhibitors indicated as adjuncts to diet and exercise to improve glycemic control in adults with type 2 diabetes. Because of proven cardiovascular benefits (5,6
The tree-based scan statistic is a statistical data mining tool that has been used for signal detection with a self-controlled design in vaccine safety studies. This disproportionality statistic adjusts for multiple testing in evaluation of thousands of potential adverse events. However, many drug safety questions are not well suited for self-controlled analysis. We propose a method that combines tree-based scan statistics with propensity score-matched analysis of new initiator cohorts, a robust design for investigations of drug safety. We conducted plasmode simulations to evaluate performance. In multiple realistic scenarios, tree-based scan statistics in cohorts that were propensity score matched to adjust for confounding outperformed tree-based scan statistics in unmatched cohorts. In scenarios where confounding moved point estimates away from the null, adjusted analyses recovered the prespecified type 1 error while unadjusted analyses inflated type 1 error. In scenarios where confounding moved point estimates toward the null, adjusted analyses preserved power, whereas unadjusted analyses greatly reduced power. Although complete adjustment of true confounders had the best performance, matching on a moderately mis-specified propensity score substantially improved type 1 error and power compared with no adjustment. When there was true elevation in risk of an adverse event, there were often co-occurring signals for clinically related concepts. TreeScan with propensity score matching shows promise as a method for screening and prioritization of potential adverse events. It should be followed by clinical review and safety studies specifically designed to quantify the magnitude of effect, with confounding control targeted to the outcome of interest.
PurposeTo develop the infrastructure to conduct timely active surveillance for safety of influenza vaccines and other medical countermeasures in the Sentinel System (formerly the Mini‐Sentinel Pilot), a Food and Drug Administration‐sponsored national surveillance system that typically relies on data that are mature, settled, and updated quarterly.MethodsThree Data Partners provided their earliest available (“fresh”) cumulative claims data on influenza vaccination and health outcomes 3–4 times on a staggered basis during the 2013–2014 influenza season, collectively producing 10 data updates. We monitored anaphylaxis in the entire population using a cohort design and seizures in children ≤4 years of age using both a self‐controlled risk interval design (primary) and a cohort design (secondary). After each data update, we conducted sequential analysis for inactivated (IIV) and live (LAIV) influenza vaccines using the Maximized Sequential Probability Ratio Test, adjusting for data‐lag.ResultsMost of the 10 sequential analyses were conducted within 6 weeks of the last care‐date in the cumulative dataset. A total of 6 682 336 doses of IIV and 782 125 doses of LAIV were captured. The primary analyses did not identify any statistical signals following IIV or LAIV. In secondary analysis, the risk of seizures was higher following concomitant IIV and PCV13 than historically after IIV in 6‐ to 23‐month‐olds (relative risk = 2.7), which requires further investigation.ConclusionsThe Sentinel System can implement a sequential analysis system that uses fresh data for medical product safety surveillance. Active surveillance using sequential analysis of fresh data holds promise for detecting clinically significant health risks early. Limitations of employing fresh data for surveillance include cost and the need for careful scrutiny of signals. © 2015 The Authors. Pharmacoepidemiology and Drug Safety Published by John Wiley & Sons Ltd.
The US Food and Drug Administration's Sentinel System was established in 2009 to use routinely collected electronic health data for improving the national capability to assess post-market medical product safety. Over more than a decade, Sentinel has become an integral part of FDA's surveillance capabilities and has been used to conduct analyses that have contributed to regulatory decisions. FDA's role in the COVID-19 pandemic response has necessitated an expansion and enhancement of Sentinel. Here we describe how the Sentinel System has supported FDA's response to the COVID-19 pandemic. We highlight new capabilities developed, key data generated to date, and lessons learned, particularly with respect to working with inpatient electronic health record data.Early in the pandemic, Sentinel developed a multi-pronged approach to support FDA's anticipated data and analytic needs. It incorporated new data sources, created a rapidly refreshed database, developed protocols to assess the natural history of COVID-19, validated a diagnosis-code based algorithm for identifying patients with COVID-19 in administrative claims data, and coordinated with other national and international initiatives.Sentinel is poised to answer important questions about the natural history of COVID-19 and is positioned to use this information to study the use, safety, and potentially the effectiveness of medical products used for COVID-19 prevention and treatment.
The self-controlled tree-temporal scan statistic—a new signal-detection method—can evaluate whether any of a wide variety of health outcomes are temporally associated with receipt of a specific vaccine, while adjusting for multiple testing. Neither health outcomes nor postvaccination potential periods of increased risk need be prespecified. Using US medical claims data in the Food and Drug Administration’s Sentinel system, we employed the method to evaluate adverse events occurring after receipt of quadrivalent human papillomavirus vaccine (4vHPV). Incident outcomes recorded in emergency department or inpatient settings within 56 days after first doses of 4vHPV received by 9- through 26.9-year-olds in 2006–2014 were identified using International Classification of Diseases, Ninth Revision, diagnosis codes and analyzed by pairing the new method with a standard hierarchical classification of diagnoses. On scanning diagnoses of 1.9 million 4vHPV recipients, 2 statistically significant categories of adverse events were found: cellulitis on days 2–3 after vaccination and “other complications of surgical and medical procedures” on days 1–3 after vaccination. Cellulitis is a known adverse event. Clinically informed investigation of electronic claims records of the patients with “other complications” did not suggest any previously unknown vaccine safety problem. Considering that thousands of potential short-term adverse events and hundreds of potential risk intervals were evaluated, these findings add significantly to the growing safety record of 4vHPV.
The Sentinel System is a major component of the United States Food and Drug Administration’s (FDA) approach to active medical product safety surveillance. While Sentinel has historically relied on large quantities of health insurance claims data, leveraging longitudinal electronic health records (EHRs) that contain more detailed clinical information, as structured and unstructured features, may address some of the current gaps in capabilities. We identify key challenges when using EHR data to investigate medical product safety in a scalable and accelerated way, outline potential solutions, and describe the Sentinel Innovation Center’s initiatives to put solutions into practice by expanding and strengthening the existing system with a query-ready, large-scale data infrastructure of linked EHR and claims data. We describe our initiatives in four strategic priority areas: (1) data infrastructure, (2) feature engineering, (3) causal inference, and (4) detection analytics, with the goal of incorporating emerging data science innovations to maximize the utility of EHR data for medical product safety surveillance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.