The prognosis for patients with acute type B aortic dissection is bleak and determined primarily by dissection-related and patient-specific risk factors, which do not appear to be readily modifiable.
Outpatient LVAD support is safe and provides improved quality of life for patients awaiting transplantation. Wearable and totally implantable LVADs should be studied as permanent treatment options for patients who are not candidates for heart transplantation.
AimsTo assess treatment decision and outcome in patients referred for transcatheter aortic valve implantation (TAVI) in addition to predictive factors of mortality after TAVI.MethodsThree-centre prospective observational study including 358 patients. Endpoints were defined according to the Valve Academic Research Consortium.ResultsOf the 358 patients referred for TAVI, TAVI was performed in 235 patients (65%), surgical aortic valve replacement (AVR) in 24 (7%) and medical therapy (MT) in 99 (28%). Reasons to decline TAVI in favour of AVR/MT were patient preference (29%), peripheral vascular disease (15%) and non-severe aortic stenosis (11%). The logistic EuroSCORE was significantly higher in patients who underwent TAVI and MT in comparison with those undergoing AVR (19 vs. 10%, p = 0.007). At 30 days, all-cause mortality and the combined safety endpoint were 9 and 24% after TAVI and 8 and 25% after AVR, respectively. All-cause mortality was significantly lower in the TAVI group compared with the MT group at 6 months, 1 year and 2 years (12% vs. 22%, 21% vs. 33% and 31% vs. 55%, respectively, p < 0.001). Multivariable analysis revealed that blood transfusion (HR: 1.19; 95% CI: 1.05–1.33), pre-existing renal failure (HR: 1.18; 95% CI: 1.06–1.33) and STS score (HR: 1.06; 95% CI: 1.02–1.10) were independent predictors of mortality at a median of 10 (IQR: 3–23) months after TAVI.ConclusionsApproximately two-thirds of the patients referred for TAVI receive this treatment with gratifying short- and long-term survival. Another 7% underwent AVR. Prognosis is poor in patients who do not receive valve replacement therapy.
Antifibrinolytic agents are used during cardiac surgery to minimize bleeding and reduce exposure to blood products. Several reports suggest that tranexamic acid (TA) can induce seizure activity in the postoperative period. To examine factors associated with postoperative seizures in patients undergoing cardiac surgery who received TA. University-affiliated hospital. Case-control study. Patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) between January 2008 and December 2009 were identified. During this time, all patients undergoing heart surgery with CPB received TA. Cases were defined as patients who developed seizures that required initiation of anticonvulsive therapy within 48 h of surgery. Exclusion criteria included subjects with preexisting epilepsy and patients in whom the convulsive episode was secondary to a new ischemic lesion on brain imaging. Controls who did not develop seizures were randomly selected from the initial cohort. From an initial cohort of 903 patients, we identified 32 patients with postoperative seizures. Four patients were excluded. Twenty-eight cases and 112 controls were analyzed. Cases were more likely to have a history of renal impairment and higher preoperative creatinine values compared with controls (1.39 ± 1.1 vs. 0.98 ± 0.02 mg/dL, P = 0.02). Significant differences in the intensive care unit, postoperative and total lengths of stay were observed. An association between high preoperative creatinine value and postoperative seizure was identified. TA may be associated with the development of postoperative seizures in patients with renal dysfunction. Doses of TA should be reduced or even avoided in this population.
Three-dimensional printing (3DP) has recently gained importance in the medical industry, especially in surgical specialties. It uses different techniques and materials based on patients’ needs, which allows bioprofessionals to design and develop unique pieces using medical imaging provided by computed tomography (CT) and magnetic resonance imaging (MRI). Therefore, the Department of Biology and Medicine and the Department of Physics and Engineering, at the Bioastronautics and Space Mechatronics Research Group, have managed and supervised an international cooperation study, in order to present a general review of the innovative surgical applications, focused on anatomical systems, such as the nervous and craniofacial system, cardiovascular system, digestive system, genitourinary system, and musculoskeletal system. Finally, the integration with augmented, mixed, virtual reality is analyzed to show the advantages of personalized treatments, taking into account the improvements for preoperative, intraoperative planning, and medical training. Also, this article explores the creation of devices and tools for space surgery to get better outcomes under changing gravity conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.